TECHNICAL INFORMATION AND TROUBLESHOOTING
Code
Message
F0118
No DSP communication
Temperature in the PP too
F0119
high�
F0130
GENERIC ERROR
Reason
This error may be caused by a faulty
cable or connection between the Main
Board and control board� Otherwise, the
Main Board and/or control board card
is faulty�
Water coolant is lacking/insufficient to
powerpack�
This error occur when the blade/drill bit
is abrouptly forced to a stop by a large
outer force�
Action
Check all cabels and cable
connections� If it doesn't help
then replace first control bard and
then Main Board one at the time�
Check that the water coolant
flows to the power pack and that
it is max 25°C and min 3�5 l/
min� If the message pops up when
the blade rotation is started - go to
the operations menu and "Water
coolant" and select "ON"� Let the
water coolant circulate the power
pack for a minute before you turn
the blade rotation on again�