Haier 1U71SABFRA Service Manual page 48

Table of Contents

Advertisement

11.2 Cooling power consumption value- temperature curves
indoor temp.
DB/WB
10℃
21/15℃
1557
24/16℃
1617
27/19℃
1681
30/22℃
1738
32/23℃
1780
35/24℃
1815
2500
2300
2100
1900
1700
1500
performance curves
power consumption temp.table
15℃
20℃
25℃
1644
1708
1802
1689
1753
1840
1731
1780
1860
1784
1852
1926
1840
1905
1980
1897
1995
2096
power consumption and temp.curves
indoor tempe.(DB/WB)
46
Performance and curves diagrams
outdoor temp.
30℃
35℃
1878
1992
1935
2048
1973
2105
2030
2162
2086
2257
2143
2313
38℃
40℃
43℃
2086
2158
2198
2135
2200
2240
2185
2257
2297
2275
2332
2372
2389
2472
2512
2427
2534
2570
10℃
15℃
20℃
25℃
30℃
35℃
38℃
40℃
43℃
Domestic air conditioner