4. Loosen the plug of the LVDS display cable from the front electronic. To do so, press the
two locking mechanisms (A) on the side of the plug and pull out the plug as shown in the
figure below.
5. Remove the adhesive tape (X) and loosen the plug of the touch cable from the front
electronic. To do so, press the locking mechanism (A) of the plug and pull out the plug as
shown in the figure below.
Save the adhesive tape.
6. Remove the adhesive tape (X) and pull out the plug of the BLI cable from the front
electronic as shown in the figure below.
Save the adhesive tape.
SIMATIC IPC277D/E 19" INOX PRO, SIMATIC IFP1900 INOX PRO
Service Manual, 11/2017, A5E35751762-AC
Extended maintenance work
4.2 Opening the device and loosening cables
13