Locking the Control Panel

Disenabling operations can prevent erroneous operations or misuse by children.
When this indicator lamp
not be activated by touching it.
Touch
button on the Control Panel to turn
1
on the indicator lamp.
All indicator lamps turn on, and then the current settings are displayed.
2
Press down
until the preset sound is heard.
Lock of the Control Panel is changed to " On " or " Off " .
The locking of the Control Panel is factory-set to " OFF " ( "
Setting of the Control Panel's lock
"
indicator lamp "
Preset sound

Door Alarm

If any door is kept opened for 1 minute or more, it is notified with sound or light.
Duration when door is open
Alarm sound
Display area
For operation
● Door alarm is also raised when a door is left open for 30 seconds or more in the energy saving mode. The Display Section starts to blink after one
minute from the opening.
● While the indicator lamp is blinking on the display area, the Control Panel remains inactive upon touching.

Door Alarm and volume adjustment of the operation sound

You can set the sound level of the alarm louder or no alarm sound.
Touch
button on the Control Panel to turn
1
on the indicator lamp.
All indicator lamps turn on, and then the current settings are displayed.
2
Press down
until the preset sound is heard.
The volume level of the operation sound is changed from " Standard " to " Louder "
or " Sound off " . Repeat the change of settings to set the operation sound you like
(see the table shown below). The sound is set to " Standard " before shipping.
Volume level
Standard
Preset sound
(Factory setting)
(Lock of the Control Panel) is illuminated, any other portion of the Control Panel will
button for 3 seconds or more
" On "
(locked)
On
Long beep
1 minute
Long beep (3 beeps)
Blinking
Light ON
button for 3 seconds or more
Louder
Sound off
2 long beeps
Long beep
Notice
● The Auto Door function will not be disabled
even when the Control Panel is locked.
In order to stop Auto Door function, unlock
the Control Panel, and touch the
for 3 seconds or more until it beeps twice.
● When connecting/disconnecting the power
plug or after recovering from electric power
" is unlit).
failure, lock of the panel for operation may
" Off "
(unlocked)
be released.
Off
2 beeps
2 minutes
Long beep (5 beeps)
Blinking
Light ON
Notice
● It is impossible to adjust the volume level of
either door alarm or operation sound only.
● When the Door Alarm is disabled, characters
on the Control Panel no longer blink.
● Even if the volume level is set to " Sound off " ,
the alarm of the Ice Maker Cleaning is raised
and the operation sound is heard when the
Auto Door is set to " ON " .
● When connecting/disconnecting the power
plug or after recovering from electric power
failure, it will return to the standard setting
Standard
where the Door Alarm sounds.
2 beeps