Disassembling the Panel Unit
Panel Board
1.
Pull out the FFC from the Ferrite Core, and remove the three screws that
secure the Panel Board.
2.
Release the hook, and remove the Panel Board from the Panel Unit.
Panel Unit
Panel Board
Hook
Positioning Hole
Figure 4-118. Removing the Panel Board
Buttons
1.
Remove the Button Power and the Button OP from the Panel Cover.
2.
Remove the LED Lens from the Panel Cover.
Button OP
Panel Cover
Figure 4-119. Removing the Buttons
When installing the Panel Board, align the positioning hole of
the Panel Board with the dowels of the Panel Cover. (See
Fig.4-19)
When installing the Panel Unit, align the positioning holes of the
Middle Housing with the dowels of the Panel Cover, then secure
them with five hooks. (See Fig.4-17, Fig.4-20.)
DISASSEMBLY/ASSEMBLY
Ferrite Core
Double-sided tape
SCREW M3x8 P-TITE (5±0.5kgfcm)
LED Lens
Button Power
Dowel
Disassembly/reassembly procedures of NX110 series
Revision C
109