Mitsubishi Electric City Multi PEFY-P-VML-E Operation Manual
Mitsubishi Electric City Multi PEFY-P-VML-E Operation Manual

Mitsubishi Electric City Multi PEFY-P-VML-E Operation Manual

Indoor unit
Hide thumbs Also See for City Multi PEFY-P-VML-E:

Advertisement

Quick Links

Air-Conditioners
INDOOR UNIT
PEFY-P-VML-E PEFY-P-VMS-E
PEFY-P-VMM-E PEFY-P-VMR-E-L/R PFFY-P-VLRM(M)-E
PEFY-P-VMH-E PLFY-P-VLMD-E
OPERATION MANUAL
For safe and correct use, please read this operation manual thoroughly before operating the air-conditioner unit.
BEDIENUNGSHANDBUCH
Zum sicheren und einwandfreien Gebrauch der Klimaanlage dieses Bedienungshandbuch vor Inbetriebnahme gründlich durchlesen.
MANUEL D'UTILISATION
Pour une utilisation correcte sans risques, veuillez lire le manuel d'utilisation en entier avant de vous servir du climatiseur.
MANUAL DE INSTRUCCIONES
Lea este manual de instrucciones hasta el final antes de poner en marcha la unidad de aire acondicionado para garantizar un uso seguro y
correcto.
ISTRUZIONI DI FUNZIONAMENTO
Leggere attentamente questi istruzioni di funzionamento prima di avviare l'unità, per un uso corretto e sicuro della stessa.
BEDIENINGSHANDLEIDING
Voor een veilig en juist gebruik moet u deze bedieningshandleiding grondig doorlezen voordat u de airconditioner gebruikt.
MANUAL DE OPERAÇÃO
Para segurança e utilização correctas, leia atentamente o manual de operação antes de pôr a funcionar a unidade de ar condicionado.
E°XEIPI¢IO O¢H°IøN XPH™Eø™
°È· ·ÛÊ¿ÏÂÈ· Î·È ÛˆÛÙ‹ ¯Ú‹ÛË, ·Ú·Î·Ï›ÛÙ ‰È·‚¿ÛÂÙ ÚÔÛ¯ÙÈο ·˘Ùfi ÙÔ ÂÁ¯ÂÈÚ›‰ÈÔ ¯Ú‹Ûˆ˜ ÚÈÓ ı¤ÛÂÙ Û ÏÂÈÙÔ˘ÚÁ›· ÙË
ÌÔÓ¿‰· ÎÏÈÌ·ÙÈÛÌÔ‡.
РУКОВОДСТВО ПО ЭКСПЛУАТАЦИИ
Для обеспечения правильного и безопасного использования следует ознакомиться с инструкциями, указанными в данном
руководстве по эксплуатации, тщательным образом до того, как приступать к использованию кондиционера.
IfiLETME ELK‹TABI
Emniyetli ve do¤ru biçimde nas›l kullan›laca¤›n› ö¤renmek için lütfen klima cihaz›n› iflletmeden önce bu elkitab›n› dikkatle okuyunuz.
PDFY-P-VM-E
PFFY-P-VLEM-E

Advertisement

Table of Contents
loading

Summary of Contents for Mitsubishi Electric City Multi PEFY-P-VML-E

  • Page 1 Air-Conditioners INDOOR UNIT PEFY-P-VML-E PEFY-P-VMS-E PDFY-P-VM-E PEFY-P-VMM-E PEFY-P-VMR-E-L/R PFFY-P-VLRM(M)-E PEFY-P-VMH-E PLFY-P-VLMD-E PFFY-P-VLEM-E OPERATION MANUAL For safe and correct use, please read this operation manual thoroughly before operating the air-conditioner unit. BEDIENUNGSHANDBUCH Zum sicheren und einwandfreien Gebrauch der Klimaanlage dieses Bedienungshandbuch vor Inbetriebnahme gründlich durchlesen. MANUEL D’UTILISATION Pour une utilisation correcte sans risques, veuillez lire le manuel d’utilisation en entier avant de vous servir du climatiseur.
  • Page 2 Controlador remoto-Botón Remote controller-Button Bottone dell’unità del comando a distanza Fernbedienungs-Taste Knop afstandbediening Touche Commande à distance Botão do controlo remoto 1 Botón [Ajuste de la temperatura] 2 Botón [TIMER MENU] 3 Botón [Modo] Botón [MONITOR/SET] Botón [BACK] 4 Botón [TIMER ON/OFF] 5 Botón [Rejilla] Botón [SET DAY] Botón [OPERATION]...
  • Page 3 Controlador remoto-Indicador Remote controller-Display Display dell’unità del comando a distanza Fernbedienung-Anzeige Display afstandbediening Affichage Commande à distance Visualização do controlo remoto A Hora actual/hora del temporizador B Indicador de control centralizado C Indicador de desconexión del temporizador D Indicador de modo del temporizador E Pantalla de modo de funcionamiento: FRÍO, DESHUMIDIFICACION,...
  • Page 4 [Fig. A] <PLFY-P20~100VLMD-E> <PLFY-P125VLMD-E> <PDFY-P-VM-E> <PEFY-P-VML-E> <PEFY-P-VMM-E> A: Filter 1: In case of rear inlet 2: In case of bottom inlet : Air Flow Bei Einlass von hinten Bei Einlass von unten Filter Luftstrom En cas d’entrée arrière En cas d’entrée sur le dessous Filtre Flux d’air En el caso de unidad interior trasera...
  • Page 5 [Fig. A] <PEFY-P-VMH-E> <PFFY-P-VLEM-E, VLRM(M)-E> <PEFY-P-VMS-E> <PEFY-P-VMR-E-L/R> A: Filter 1: In case of rear inlet 2: In case of bottom inlet : Air Flow Bei Einlass von hinten Bei Einlass von unten Filter Luftstrom En cas d’entrée arrière En cas d’entrée sur le dessous Filtre Flux d’air En el caso de unidad interior trasera...
  • Page 6: Table Of Contents

    If the unit is not grounded properly, electric shock may result. • Use only accessories authorized by Mitsubishi Electric and ask your • Check frequently that the ground wire from the outdoor unit is properly dealer or an authorized company to install them.
  • Page 7: Disposing Of The Unit

    Warning: your dealer. Leaving the unit as it is under such conditions can result in • Do not remove the front panel or the fan guard from the outdoor unit fire or failure. when it is running. You could be injured if you touch rotating, hot or high- •...
  • Page 8: Room Temperature Adjustment

    PEFY-P40~140VMH, PFFY-P-VLEM, PFFY-P-VLRM For fan PDFY-P100·125VM, PEFY-P100~140-VMM series Press the 3 [Mode (BACK)] Button and bring up the “ FAN” display. Fan speed : 2 stages • The fan operation functions to circulate the air in the room. Display: (Low)→ (High) •...
  • Page 9: Ventilation

    3.6. Ventilation 3.7. Others • The ventilation unit (OA processing unit or LOSSNAY) automatically goes into : Displayed when control is executed by a separately operation when the indoor unit that is interlocked with it goes into operation. sold centralized control unit, etc. If the 8 [Ventilation] button is pressed while the indoor unit is stopped, only the STAND BY •...
  • Page 10: Troubleshooting

    6. Troubleshooting Before you ask for repair service, check the following points: State of Machine Remote Controller Cause Troubleshooting “'” display is not lit up. Power failure Press the [ON/OFF] button after power restoration. No display appears even The power supply is turned OFF. Turn the power supply ON.
  • Page 11: Installation, Transferring Works, And Checking

    7. Installation, transferring works, and checking Regarding place for installation • Never connect the grounding wire to a gas pipe, water pipe, arrester, or Consult with your dealer for details on installation and transferring the installation. telephone grounding wire. For details, consult with your dealer. •...
  • Page 12 PEFY-P-VML-E series Model P20VML-E P25VML-E P32VML-E Item Power source ~220-240V 50/60Hz Cooling capacity*1 / Heating capacity*1 2.2/2.5 2.8/3.2 3.6/4.0 Dimension Height / Width / Depth 225/720/550 225/720/550 225/720/550 Net weight Airflow rate (Low-Middle-High) /min 4.8/5.8/7.9 4.8/5.8/7.9 4.8/5.8/9.5 External static pressure Noise level (Low-Middle-High)*5 dB(A) 25/29/36...
  • Page 13 PFFY-P-VLEM-E/PFFY-P-VLRM(M)-E series Model P20VLEM-E P25VLEM-E P32VLEM-E P40VLEM-E P50VLEM-E P63VLEM-E Item Power source ~220-240V 50Hz / ~208V-230V 60Hz Cooling capacity*1/Heating capacity*1 2.2/2.5 2.8/3.2 3.6/4.0 4.5/5.0 5.6/6.3 7.1/8.0 Dimension Height / Width / Depth 630/1,050/220 630/1,050/220 630/1,170/220 630/1,170/220 630/1,410/220 630/1,410/220 Net weight Airflow rate (Low-High) /min 5.5-6.5...
  • Page 14 Notes: * Operation temperature of indoor unit. Cooling mode: 15 °C WB - 24 °C WB Heating mode: 15 °C DB - 27 °C DB *1 Cooling/Heating capacity indicates the maximum value at operation under the following condition. Cooling: Indoor: 27 °C DB/19 °C WB Outdoor: 35 °C DB Heating: Indoor: 20 °C DB Outdoor: 7 °C DB/6 °C WB...
  • Page 15 This product is designed and intended for use in the residential, commer- cial and light-industrial environment. • Low Voltage Directive 73/23/EEC The product at hand is • Electromagnetic Compatibility Directive 89/ based on the following EU regulations: 336/EEC Please be sure to put the contact address/telephone number on this manual before handing it to the customer.