Sanyo SAP-K181A Technical & Service Manual page 10

System
Table of Contents

Advertisement

2-2-2. Outdoor Unit
Outdoor Unit
SAP – C181A
Compressor
Type
Compressor model
Nominal output
Compressor oil ... Amount
Coil resistance (Ambient temp. 25°C)
Safety devices
Type
Overload relay
Operating temp.
Operating amp.(Ambient temp. 25°C)
Run capacitor
Crank case heater
Fan & Fan Motor
Type
Q'ty ... Dia.
Fan motor model ... Q'ty
No. of poles ... rpm (240 V, High)
Nominal output
Coil resistance (Ambient temp. 20°C)
Safety devices
Type
Operating temp.
Run capacitor
Heat Exch. Coil
Coil
Rows
Fin pitch
Face area
External Finish
W
cc
Open
°C
Close
°C
µF
VAC
W
Open
°C
Close
°C
µF
VAC
mm
m
2
6
Rotary (Hermetic)
C-2R170H5T 80827445
1,700
SUNISO 4GSD-T ... 750
C–R : 1.353
C–S : 3.422
Internal protector
Automatic opening
Automatic reclosing
40.0
400
Propeller
1 ... ø420
KFG6S-51A5P-S ... 1
6 ... 880
50
WHT-BRN : 67.09
WHT-YEL : 68.12
YEL-PNK : 15.66
Internal protector
130±8
Automatic reclosing
4.0
440
Aluminum plate fin / Copper tube
1
1.3
0.506
Acrylic baked-on enamel finish
DATA SUBJECT TO CHANGE WITHOUT NOTICE.