Sanyo SAP-K181A Technical & Service Manual page 11

System
Table of Contents

Advertisement

Outdoor Unit
SAP – C241A
Compressor
Type
Compressor model
Nominal output
Compressor oil ... Amount
Coil resistance (Ambient temp. 25°C)
Safety devices
Type
Overload relay
Operating temp.
Operating amp.(Ambient temp. 25°C)
Run capacitor
Crank case heater
Fan & Fan Motor
Type
Q'ty ... Dia.
Fan motor model ... Q'ty
No. of poles ... rpm (240 V, High)
Nominal output
Coil resistance (Ambient temp. 20°C)
Safety devices
Type
Operating temp.
Run capacitor
Heat Exch. Coil
Coil
Rows
Fin pitch
Face area
External Finish
W
cc
Open
°C
Close
°C
Automatic reclosing
µF
VAC
W
Open
°C
Close
°C
µF
VAC
mm
m
2
7
Rotary (Hermetic)
C-R221H5S 80687145
2,200
SUNISO 4GSD-T ... 1,350
C–R : 0.777
C–S : 2.408
Internal protector
Automatic opening
40.0
400
Propeller
1 ... ø420
KFG6S-51D5P-S ... 1
6 ... 890
50
WHT-BRN : 56.09
WHT-YEL : 42.13
YEL-PNK : 15.99
Internal protector
130±8
Automatic reclosing
4.0
440
Aluminum plate fin / Copper tube
1.2
0.499
Acrylic baked-on enamel finish
DATA SUBJECT TO CHANGE WITHOUT NOTICE.
External(OLR T)
OL-D24
150±5
63±11
Trip in 6 to 16 sec. at 59A
2

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sap-k241aSap-c181aSap-c241a