4. REFRIGERANT FLOW DIAGRAM

Indoor Unit
SAP – K181A
Indoor Unit
Indoor Unit
SAP – K241A
Indoor Unit
Insulation of Refrigerant Tubing
IMPORTANT
Because capillary tubing is used in the outdoor unit, both the
wide and narrow tubes of this air conditioner become cold. To
prevent heat loss and wet floors due to dripping of
condensation, both tubes must be well insulated with a
proper insulation material. The thickness of the insulation
should be a min. 8 mm.
CAUTION
Wide tube
service
valve
Wide tube
O.D.
ø12.7 mm
(1/2 ")
Narrow
tube
service
Narrow tube
valve
O.D.
ø6.35 mm
(1/4")
Wide tube
service
Wide tube
valve
O.D.
ø15.88 mm
(5/8 ")
Narrow
tube
service
Narrow tube
valve
O.D.
ø6.35 mm
(1/4")
After a tube has been insulated,
never try to bend it into a narrow
curve because it can cause the tube
to break or crack.
Outdoor Unit
Outdoor Unit
Compressor
Accumulator
Capillary for
liquid injection
Capillary tube
Outdoor Unit
Outdoor Unit
Compressor
Muffler
Accumulator
Capillary for
liquid injection
Strainer
Capillary tube
12
SAP – C181A
SAP – C241A
Insulation
Thickness:
Min. 8 mm
Wide tube
Thickness:
Min. 8 mm
Narrow tube