Installing the Anti-siphon Fill
Receptacle
1. Remove the rubber cap from the stud on the tank strap
(Fig. 2).
4
1
2
Figure 2
1. Fill receptacle bracket
2. Stud
3. Flange nut, 5/16 inch
2. Place the fill receptacle bracket over the stud and secure
it with a flange nut (5/16 inch) (Fig. 2).
3. Place the threaded end of the 90 degree elbow fitting
through the bracket and thread the quick coupler onto it,
securing it to the bracket (Fig. 2).
Note: Install the fitting with the open end pointing toward
the tank opening so the water will arc into the tank when
you fill it.
4. Install the hose adapter into the quick coupler (Fig. 2).
5. Lock the adapter into place by swinging the levers
toward the adapter and then secure them with the
hairpin cotters.
Installing the Spray Pro
Monitor
1. Install the monitor bracket on the dash (Fig. 3) using 2
flange-head bolts (1/4 x 3/4 inch) and 2 flange nuts
(1/4 inch).
5
6
3
1865
4. 90 degree elbow fitting
5. Quick coupler
6. Hose adapter
12
1
4
Figure 3
1. Spray Pro monitor
2. Bracket
2. Loosely install the 2 carriage bolts, rubber washers, and
knobs on the bracket as illustrated in Figure 3 and 4.
Note: Install the carriage bolts and rubber washers inside of
the bracket and the knobs on the outside.
2
1
4
Figure 4
1. Carriage bolt
2. Rubber washer
3. Remove the large grommet from the hole in the dash
and thread the cables on the monitor through the
grommet and the dash.
4. Install the grommet into the dash.
5. Install the Spray Pro monitor over the carriage bolt
heads (Fig. 3) and tighten the knobs to secure it.
4
2
3
3. Flange-head bolts,
1/4 x 3/4 inch
4. Knob
3
3. Knob
4. Bracket