How To Change The Value Of Bit Pointer Parameter To Fixed 0 (False) Or 1 (True) - ABB ACSM1 Control Panel User Manual

Hide thumbs Also See for ACSM1 Control Panel:
Table of Contents

Advertisement

How to change the value of bit pointer parameter to fixed 0 (FALSE) or 1 (TRUE)

The bit pointer parameter can be fixed to constant value of 0 (FALSE) or 1 (TRUE).
When adjusting a bit pointer parameter on the control panel, CONST is selected in
order to fix the value to 0 (displayed as C.FALSE.) or 1 (C.TRUE.).
For more information, see appropriate Firmware Manual.
Step
Action
1.
Go to the Main menu by pressing
EXIT
by pressing
2.
Go to the Parameters option by selecting PARAMETERS on the menu with
keys
and
3.
Select the appropriate parameter group with keys
bit pointer parameter 12.04 DI01 OUT PTR is used as an example.
SEL
4.
Press
to select the appropriate parameter group. Select the appropriate
parameter with keys
shown below its name.
EDIT
5.
Press
.
Select CONST with keys
NEXT
6.
Press
.
7.
Specify a new constant value (TRUE or FALSE) for the bit pointer parameter
with keys
MENU
if you are in the Output mode, otherwise
repeatedly until you get to the Main menu.
ENTER
, and pressing
and
. Current value of each parameter is
and
and
.
.
and
. Here the
.
Display
LOC
MAIN MENU
PARAMETERS
FAULT LOGGER
TIME & DATE
EXIT
00:00
ENTER
LOC
PAR GROUPS
01 ACTUAL VALUES
02 I/O VALUES
03 CONTROL VALUES
04 POS CTRL VALUES
06 DRIVE STATUS
EXIT
00:00
SEL
LOC
PAR GROUPS
12 DIGITAL IO
13 ANALOGUE INPUTS
15 ANALOGUE OUTPUTS
16 SYSTEM
17 PANEL DISPLAY
EXIT
00:00
SEL
LOC
PARAMETERS
1201 DI01
CONF9901
1202 DI02 CONF
1203 DI03 CONF
1204 DI01 OUT PTR
P.06.02.02
EXIT
00:00
EDIT
LOC
PAR EDIT
1204 DI01 OUT PTR
Pointer
CANCEL
00:00
NEXT
LOC
PAR EDIT
1204 DI01 OUT PTR
Const
CANCEL
00:00
NEXT
LOC
PAR EDIT
1204 DI01 OUT PTR
C.FALSE
[0]
CANCEL
00:00
SAVE
LOC
PAR EDIT
1204 DI01 OUT PTR
C.TRUE
[1]
CANCEL
00:00
SAVE
Operation
29
1
01
12

Advertisement

Table of Contents
loading

Table of Contents