Internal Fan Replacement - ABB ACS355 Series Supplement Manual

Drives with ip66/67 / ul type 4x enclosure (0.37...7.5 kw, 0.5...10 hp)
Hide thumbs Also See for ACS355 Series:
Table of Contents

Advertisement

Internal fan replacement

1. Stop the drive and disconnect it from the AC power source.
2. Remove the front cover.
3. Open the screw(s) holding the fan in place (1 screw in R1, 2 screws in R3)
4. Free the fan cable from the clip.
5. Disconnect the fan cable.
6. Remove the fan holder.
7. Install the new fan in reverse order. The tightening torque is 1.2 N·m for all
screws.
8. Restore power.
R1
R3
3