Delivery check

Check that there are no signs of damage. Notify the shipper immediately if damaged
components are found.
Before attempting installation and operation, check the information on the type
designation label of the drive to verify that the drive is of the correct type. The type
designation label is attached to the left side of the drive. An example label and
explanation of the label contents are shown below.
ACS355 03E 08A8 4+B063
lllllllllllllllllllllllllllllllllllllll
IP66/67 / UL Type 4X
2
Indoor Use Only
S/N MYYWWRXXXX
llllllllllllllllllllllllllllllllllllllll
4 kW (5 HP)
3
U1
3~380...480 V
3AUA0000058163
I1
13.6 A
RoHS
f1
48...63 Hz
U2
3~0...U1 V
I2
8.8 A (150% 1/10 min)
f2
0...600 Hz
Type designation label

Before installation

See the ACS355 user's manual.

Requirements for the installation site

See chapter
Wall
The wall should be as close to vertical and even as possible, of non-flammable
material and strong enough to carry the weight of the drive.
Floor
The floor/material below the installation should be non-flammable.
Free space around the drive
The required free space for cooling above and below the drive is 75 mm (3 in.).
For hygienic installation, ensure that there is enough free space around the drive to
clean it. There should be free space in front of the drive, above and below it, on
either side of it, and also between its back and the wall it is mounted onto. To make
the clearance from the wall large enough, use spacers and fastening lugs.
Buy: www.ValinOnline.com | Phone 844-385-3099 | Email: CustomerService@valin.com
1
4
5
6
Technical data
for the allowed operation conditions of the drive.
1 Type designation, see section
2 Degree of protection by enclosure (IP and UL/NEMA)
3 Nominal ratings, see section
4 Serial number of format YWWRXXXXWS, where
M:
Manufacturer
Y:
09, 10, 11, ... for 2009, 2010, 2011, ...
WW:
01, 02, 03, ... for week 1, week 2, week 3, ...
R:
A, B, C, ... for product revision number
XXXX: Integer starting every week from 0001
5 ABB MRP code of the drive
6 RoHS mark, CE marking, UL marking, and TÜV
NORD, C-Tick and NSF marks (the label of your drive
shows the valid markings)
35
Type code
on page
31
Ratings
on page 50.
Mechanical installation

Advertisement

Table of Contents
loading

This manual is also suitable for:

Acs355-03e-08a8-4+b063

Table of Contents