Mitsubishi Electric CITY MULTI PEFY-P20VMA-E3 Operation Manual

Mitsubishi Electric CITY MULTI PEFY-P20VMA-E3 Operation Manual

Indoor unit
Hide thumbs Also See for CITY MULTI PEFY-P20VMA-E3:

Advertisement

Air-Conditioners
INDOOR UNIT
PEFY-P20,25,32,40,50,63,71,80,100,125,140VMA-E3
PEFY-P20,25,32,40,50,63,71,80,100,125,140VMAL-E3
OPERATION MANUAL
For safe and correct use, please read this operation manual thoroughly before operating the air-conditioner unit.
<ORIGINAL>

Advertisement

Table of Contents
loading

Summary of Contents for Mitsubishi Electric CITY MULTI PEFY-P20VMA-E3

  • Page 1 <ORIGINAL> Air-Conditioners INDOOR UNIT PEFY-P20,25,32,40,50,63,71,80,100,125,140VMA-E3 PEFY-P20,25,32,40,50,63,71,80,100,125,140VMAL-E3 OPERATION MANUAL For safe and correct use, please read this operation manual thoroughly before operating the air-conditioner unit.
  • Page 2 [Fig. A] <PEFY-P-VMA(L)-E3> ①: Air inlet on the rear ②: Air inlet at the bottom Ⓐ: Filter Air flow Lufteinlass auf der Rückseite Lufteinlass auf der Unterseite Filter Luftfluss Admission d'air par l'arrière Admission d'air par le bas Filtre Flux d'air Entrada de aire en la parte posterior Entrada de aire en la parte inferior Filtro...
  • Page 3 Wired remote controller Controller interface ⑤ ⑥ ③ ④ ② ① Function buttons ⑦ ⑧ ⑨ ⑩ ① [ON/OFF] button The functions of the function buttons change depending on the screen. Press to turn ON/OFF the indoor unit. Refer to the button function guide that appears at the bottom of the LCD for the functions they serve on a given screen.
  • Page 4 Display The main display can be displayed in two different modes: “Full” and “Basic.” The factory setting is “Full.” To switch to the “Basic” mode, change the setting on the Main display setting. ▌ Full mode ▌ Basic mode * All icons are displayed for explanation. ㉓...
  • Page 5: Table Of Contents

    If the unit is installed improperly, 6) Grounding water leakage, electric shock or fire may result. • Use only accessories authorized by Mitsubishi Electric and ask your Caution: dealer or an authorized company to install them. If accessories are • The unit must be properly grounded.
  • Page 6: During Operation

    1.2. During operation In case of failure Warning: Warning: • Never remodel the air conditioner. Consult your dealer for any repair or • Do not splash water over the unit and do not touch the unit with wet service. Improper repair work can result in water leakage, electric shock, hands.
  • Page 7: How To Operate

    3. How to operate Caution: 3.1. Turning ON/OFF • Never expose your body directly to cool air for a long time. Excessive exposure to cool air is bad for your health, and should therefore be avoided. Press the [ON/OFF] button. • When the air-conditioner is used together with burners, thoroughly The ON/OFF lamp will light up in green, and ventilate the area.
  • Page 8: Set Temperature

    3.3. Set temperature 3.4. Fan speed <Cool, Dry, Heat, and Auto (single set point)> Press the [F4] button to go through the fan Press the [F2] button to decrease the set speeds in the following order. temperature, and press the [F3] button to increase.
  • Page 9: The Smart Way To Use

    4. The smart way to use Even minimal steps to care for your air conditioner can help make its use far Prevent intrusion of heat during air-cooling more effective in terms of air-conditioning effect, electricity charges, etc. • To prevent the intrusion of heat during cooling operation, provide a curtain or a blind on the window to block out direct sunlight.
  • Page 10: Troubleshooting

    6. Troubleshooting When an error occurs, the following screen will appear and the operation LED will blink. Check the error status, stop the operation, and consult your dealer. Error code, error unit, refrigerant address, unit model name, and serial number will appear. The model name and serial number will appear only if the information have been registered.
  • Page 11: Installation, Transferring Works, And Checking

    • The air conditioner sometimes snaps or clicks at the beginning or end of The following symptoms are not air conditioner failures: • The air blown out from the air conditioner can sometimes give off odors. This is cooling/heating operation. This is the sound of friction on the front panel and due to cigarette smoke contained in the air of the room, the smell of cosmetics, other sections due to expansion and contraction caused by temperature the walls, furniture, etc., absorbed in the air conditioner.
  • Page 12: Specifications

    8. Specifications PEFY-P-VMA(L)-E3 series P20VMA(L)-E3 P25VMA(L)-E3 P32VMA(L)-E3 P40VMA(L)-E3 P50VMA(L)-E3 Power source ~220-240 V 50Hz Cooling capacity / Heating capacity 2.2/2.5 2.8/3.2 3.6/4.0 4.5/5.0 5.6/6.3 Dimension Height / Width / Depth 250/700/732 250/700/732 250/700/732 250/900/732 250/900/732 Net weight 21 (20) 21 (20) 21 (20) 25 (24) 25 (24)
  • Page 13 63-62-61 Note: Recycle Rating condition Your MITSUBISHI ELECTRIC product is designed and manufactured with high quality Cooling - Indoor: 27ºC DB, 19ºC WB materials and components which can be recycled and reused. Electrical and electronic Outdoor: 35ºC DB, 24ºC WB equipment, at their end-of-life, should be disposed of separately from your household Heating - Indoor: 20ºC DB, 15ºC WB...
  • Page 14 Wärmeleistung Отоплителна мощност Küttevõimsus Puissance calorifique Wydajność grzewcza Sildīšanas jauda Verwarmingsvermogen Kapaċità tat-tisħin Šildymo pajėgumas Potencia de calefacción Lämmitysteho Kapacitet grijanja Ⓔ Capacità di riscaldamento Topný výkon Varmekapasitet Θερμαντική ισχύς Vykurovací výkon Isıtma Kapasitesi Potência de aquecimento Fűtőteljesítmény Отопительная мощность Varmeydelse Zmogljivost ogrevanja Uppvärmningskapacitet...
  • Page 15 2018 manufacture MITSUBISHI ELECTRIC CORPORATION HEAD OFFICE: TOKYO BUILDING 2-7-3, MARUNOUCHI, CHIYODA-KU, TOKYO 100-8310, JAPAN Manufacturer AUTHORIZED REPRESENTATIVE IN EU: MITSUBISHI ELECTRIC EUROPE B.V.HARMAN HOUSE, 1GEORGE STREET, UXBRIDGE, MIDDLESEX UB8 1QQ, U.K. COMMERCIAL REGISTRATION NO.33279602 PEFY- PEFY- PEFY- PEFY- PEFY-...
  • Page 16 MITSUBISHI ELECTRIC, PEFY-P20VMA-E*, PEFY-P25VMA-E*, PEFY-P32VMA-E*, PEFY-P40VMA-E*, PEFY-P50VMA-E*, PEFY-P63VMA-E*, PEFY-P71VMA-E*, PEFY-P80VMA-E*, PEFY-P100VMA-E*, PEFY-P125VMA-E*, PEFY-P140VMA-E*...
  • Page 17 <ENGLISH> <PORTUGUÊS> English is original. The other languages versions are translation of the original. O idioma original é o inglês. As versões em outros idiomas são traduções do idioma original. CAUTION CUIDADO • Refrigerant leakage may cause suffocation. Provide ventilation in accordance with EN378-1. •...
  • Page 18 <MAGYAR> Az eredeti szöveg angol nyelven íródott. A más nyelven írt változatok az eredeti szöveg fordításai. FIGYELMEZTETÉS • A hűtőközeg szivárgása fulladást okozhat. Gondoskodjon a szellőzésről az EN378-1 szerint. • Feltétlenül gondoskodjon a csövek szigeteléséről. A fedetlen csövek közvetlen megérintése égési vagy fagyási sérülést okozhat.
  • Page 20 This product is designed and intended for use in the residential, commercial and light-industrial environment. The product at hand is based on the following EU regulations: • Low Voltage Directive 2014/35/EU • Electromagnetic Compatibility Directive 2014/30/EU • Machinery Directive 2006/42/EC Please be sure to put the contact address/telephone number on this manual before handing it to the customer.

Table of Contents