I Setting the jumper plug to switch the C terminal
The jumper plug for switching the C terminal on the probe header is used to switch the C terminal
capacitive-termination.
A 0.1 µF capacitor is mounted on the probe header to perform C terminal capacitive-termination.
Depending on the operating environment, change the setting of the jumper plug to select whether C
terminal capacitive-termination is performed on a user system or on the probe header. When the
product is delivered, the jumper plug is set to side 1 (C terminal capacitive-termination is done on the
user system).
To switch to the capacitor on the probe header, set the jumper plug to side 3.
WARNING
Electric shock
4
C terminal capacitive-
termination is performed
on a user system.
Figure 3-2 Setting the jumper plug to switch the C terminal
To prevent an electric shock when setting the jumper plug, turn off the product and any
connected devices and unplug the power cable from the outlet before setting the jumper
plug.
C terminal capacitive-
termination is performed
on the probe header.