Aftertreatment Device Manual Regeneration; Manual Regeneration Procedure - Hitachi ZW 550-6 Operator's Manual

Wheel loader
Table of Contents

Advertisement

Aftertreatment Device Manual Regeneration

When manual regeneration is needed, symbol (1) and
service indicator (2) as shown to the right will be displayed.
Perform manual regeneration in the following procedure.
IMPORTANT:
Park the machine in a safe area where exhaust
temperatures will not damage property or other
potential flammable sources.
Be sure that there are no flammable materials in the
engine area, including, but not limited to:
 Coal dust.
 Wood chip particles, saw dust.
 Animal feed products (straw, hay, grain dust, etc.)
 Inorganic man made debris; plastics, paper, refuse, etc.
 Any other loose flammable debris.

Manual Regeneration Procedure

1. Park the machine in a safe and open place. Place the
transmission in neutral. Apply parking brake. Lower the
front attachment level to the ground.
2. Verify that items are set as shown below.
Forward/Reverse Switch
Accelerator Pedal
Parking Brake Switch
Loading Control Lock Switch
(4)
Aftertreatment Device
Regeneration Inhibited
Setting
Hydraulic oil temperature
Coolant temperature
Remaining fuel alarm does not light.
DEF/AdBlue® alarm does not occur.
3. Press the aftertreatment device regeneration switch (3).
f
NOTE:
 When "Aftertreatment Device Regeneration Inhibited"
is preset to ON, manual regeneration cannot be started.
Refer to page 1-57.
 Refer to pages 1-5 and 1-35 for Automatic Regeneration
and more information.
OPERATING THE MACHINE
:
N (Neutral)
:
UP (OFF)
:
ON
:
LOCK ( )
OFF
:
5~70°C (41~158°F)
:
70°C (158°F) or
:
higher
5-13
1
2
Basic Screen
Manual Regeneration Request Screen
1
Rear View Camera Display
2
Basic Screen
(When Rear View Camera ON)
4
3
MNHG-01-280EN
MNHG-01-282EN
MNHG-01-281EN
3
115MNEC-07-01
MDAA-05-002

Advertisement

Table of Contents

Troubleshooting

loading

Table of Contents