Replacement Of 3D Sensor; Replacement Of Nozzle And Detergent Case A - Panasonic NA-D106X1 Service Manual

Table of Contents

Advertisement

8.7.2.

Replacement of 3D sensor

1. After replacement Panel A, Dry filter, Filter frame and Top
board (8.1), remove the 2 3D sensor fixing screws, 2
Clamping bands and 1 Connector.
8.7.3.
Replacement of Nozzle and
Detergent case A
1. After performing the procedures for Replacement of
Panel A, Dry filter, Filter frame and Top board (8.1),
Replacement of Back panel (8.3.1), remove 4 Body
support A mounting screws.
*The Rinse case lid and Detergent case B will be used to
attach to the service Nozzle and Detergent case A during
replacement.
2. Remove the 1 Nozzle fixing screw and 5 Clamping bands
fixing the lead wire, and then remove the Lead wire of the
Water level sensor from 3 hooks.
3. Lift the Nozzle up from the product and remove the
Feeding hose A and fixing hose clamp.
4. Remove 2 Clamping bands fixing the Air tube from the
rear side of body.
35