4.2.4
Contact Assignments
The S-80 is equipped with 6 "digital" contacts. All contacts can be programmed to be either open or
closed in the horizontal position and then programmed to any angular degree where the contact
changes state (from 1 to 88 degrees). The contacts are dedicated as follows:
Contact #1 (GP or Gate Position) is dedicated for the position of the gate. This is typically used
for the control of the flashing lights and/or to indicate that the gate arm is in the vertical
position.
Contact #2 (GD or Gate Down) is dedicated for determining that the gate arm is in the down
position.
Contacts #3, #4, and #5 are spare contacts. These can be used for traffic-preemption, etc.
Contact #6 (Bell) is dedicated for control of the bell.
Refer to Section 5 for detailed programming instructions of the contacts. Refer to Section 7 to
troubleshoot the contacts.
Contact
Number
1 GP
2 GD
3
4
5
6
SIG-QG-21-01
Version: A
Table 4-3 S-80 Digital Contacts Default Functions
Function of Contact
Gate Position (GP)
Gate Down (GD)
Spare
Spare
Spare
Bell
ENTRANCE GATE INSTALLATION AND SETUP
Default Contact State
in Horizontal Position
Open
Closed
Open
Open
Open
Open
4-13
Default Contact State
Change Angle
Closes at 83°
Opens at 5°
Closes at 5°
Closes at 5°
Closes at 5°
Closes at 5°
NOVEMBER 2021