ABB AquaMaster Quick Reference Manual

Electronic commercial water meter
Hide thumbs Also See for AquaMaster:

Advertisement

Quick Links

All manuals and user guides at all-guides.com
Quick Reference Guide
Electronic Commercial Water Meter
IM/AM/QRG_13
TM
AquaMaster
ABB Limited
Oldends Lane, Stonehouse, Gloucestershire, GL10 3TA, UK
Tel: +44 (0)1453 826661 Fax: +44 (0)1453 829671
Printed in UK (07.05) © ABB 2005
1

Advertisement

Table of Contents
loading

Summary of Contents for ABB AquaMaster

  • Page 1 All manuals and user guides at all-guides.com Quick Reference Guide Electronic Commercial Water Meter IM/AM/QRG_13 AquaMaster ABB Limited Oldends Lane, Stonehouse, Gloucestershire, GL10 3TA, UK Tel: +44 (0)1453 826661 Fax: +44 (0)1453 829671 Printed in UK (07.05) © ABB 2005...
  • Page 2: Controls And Display

    [Edit = SPACE][Exit = ESC] To access programming mode, connect the 1.0 Information AquaMaster to a computer via either of the serial port connections – see Instruction Manual ('Local or Remote Computer Connection' sections). Use serial port settings: Baud: 4800; Data bits 8;...
  • Page 3: Security Access

    All manuals and user guides at all-guides.com …PROGRAMMING Further key operations access the menus as follows: = Menu Displayed Text; = User entered data ; = Function Key 2.0 Measurements 1.0 Information AquaMaster 12:31:00 ABB Limited 25/12/1998 Stonehouse Test Mode Flow etc.
  • Page 4: Parameter Changes

    To write a new value to a variable, type , the variable number, and the new value required, followed > . In both cases the AquaMaster will reply with the new value of the variable (or a reason for failure) e.g.: Where >217 <0>217=42 217 is the number for the flow rate <0>...
  • Page 5: Menu Layout

    All manuals and user guides at all-guides.com MENU LAYOUT CLI Value r a l Function y t i Security Access Level f f i r f f i r . t t e t i / t t . t t .
  • Page 6 All manuals and user guides at all-guides.com MENU LAYOUT t i x r i f t i x s t i z i l s t i b i l o i t s t i t i x t i n i l a l a i s t i...
  • Page 7: Tariff Control

    All manuals and user guides at all-guides.com TARIFF CONTROL Notes toTariff Control: The Tariff Control menu is used for defining Tariff A only. Tariff B is always the opposite of Tariff A. Daily Cycle Start Time defines the start of normal day time. Weekly Cycle Start Day defines the first day of the weekend (from 00:00).
  • Page 8: Scanreader Option Interface Settings

    Reader as 123456. Invalid characters will be ignored. 326 Adapter Code 4 0 = ScanCoder 1 = AquaMaster Default setting is 0 Selects the error code capability of the interface. '0' will provide no error code information. '1' will provide extended error code information to...

Table of Contents