ABB A200-L Operation Manual page 32

Turbocharger
Hide thumbs Also See for A200-L:
Table of Contents

Advertisement

Operation Manual / A200-L
4 Commissioning / 4.2 Inspection procedures
4.2.2
Checks before commissioning
Filter mat (if available)
Check for damage and contamination.
u
Lubricating system
CAUTION
Contaminated oil
Serious damage to engine or property can be caused by dirt and solid ma-
terial particles in the oil.
For the initial commissioning phase and after all service work, flush the
u
complete lubricating system with warm oil.
Use special running-in filters when running in the engine and after all ser-
u
vice work on the lubricating system.
Check that the oil filter is clean before commissioning.
u
Check the oil pressure in the oil supply pipes.
u
Warning plates
Check whether warning plates are present and legible.
u
Check whether the protective sheets have been removed from new warning plates.
u
4.2.3
Checks after commissioning (engine in idle mode)
Lubricating system
Check the oil pressure in the oil supply pipes.
u
Check oil inlet temperature.
u
The admissible values are specified in section Oil supply.
Gas, air and oil pipes
After starting the engine, check all gas, air and oil pipes for leaks.
u
© Copyright 2021 ABB. All rights reserved.
HZTL4036_EN
Rev.T
December 2021

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

A255-lA260-lA265-lA270-lA275-lA280-l ... Show all

Table of Contents