Assembly

5.2 Preparations for installation

Loss of conformity with European directives
In the delivery state, the machine corresponds to the requirements of the European
directives. Unauthorized changes or modifications to the machine lead to the loss of
conformity with European Directives and the loss of the associated warranty.
Explosion hazard when making modifications to the machine
Modifications to the machine, such as drilling or further mechanical processing, are not
permitted or may only be carried out by the manufacturer. Otherwise an explosion can occur
in an explosive atmosphere. This can result in death, serious injury or material damage.
• Where necessary, contact the Service Center (Page 143).
5.2
Preparations for installation
5.2.1

Requirements for installation

The following requirements must be satisfied prior to starting installation work:
• Staff have access to the operating and installation instructions.
• The machine is unpacked and ready for mounting at the installation location.
• Measure the insulation resistance of the winding before starting any installation work. If
the insulation resistance lies below the specified value, take appropriate remedial
measures. These remedial measures may necessitate the machine being removed again
and transported.
Note
Note also the technical data on the rating plates on the motor enclosure.
NOTICE
Damage to the motor
To avoid material damage, before commissioning, check whether the correct direction of
rotation of the machine has been set on the customer side, e.g. by decoupling from the
driven load.
52
1MB..5/6 shaft height 71 ... 355
Operating Instructions, 10/2021, A5E41926185A