8.20. Remove the C1-Board
1. Remove the Control button unit. (See section 8.9.)
2. Remove the Support metal (C). (See section 8.17.)
3. Remove the Support metal (R). (See section 8.18.)
4. Remove the Vertical bar-down assy. (See section 8.19.)
5. Remove the flexible cables holder fastening screws (×10
).
6. Disconnect the flexible cables (CB1, CB2, CB3, CB4 and
CB5).
7. Disconnect the flexible cable (C10).
8. Disconnect the connector (C14).
9. Remove the screws (×5
8.21. Remove the C2-Board
1. Remove the Support metal (C). (See section 8.17.)
2. Remove the flexible cables holder fastening screws (×10
).
3. Disconnect the flexible cables (CB6, CB7, CB8, CB9 and
CB10).
4. Disconnect the flexible cables (C20, C21 and C26).
5. Remove the screws (×5
8.22. Remove the C3-Board
1. Remove the Tuner unit. (See section 8.5.)
2. Remove the Support metal (C). (See section 8.17.)
3. Remove the Support metal (L). (See section 8.18.)
4. Remove the Vertical bar-down assy. (See section 8.19.)
5. Remove the flexible cables holder fastening screws (×10
).
6. Disconnect the flexible cables (CB11, CB12, CB13, CB14
and CB15).
7. Disconnect the flexible cables (C31 and C36).
8. Disconnect the connectors (C33 and C35).
9. Remove the screws (×5
) and remove the C1-Board.
) and remove the C2-Board.
) and remove the C3-Board.
8.23. Remove the Plasma panel sec-
tion from the Cabinet assy
(glass)
1. Remove the cabinet assy and the plasma panel fastening
, ×4
screws (×12
2. For leaving the plasma panel from the front frame, pull the
bottom of the cabinet assy forward, lift, and remove.
26
).