Mitsubishi Electric FR-A5NP Instruction Manual page 22

Transistorized inverter
Hide thumbs Also See for FR-A5NP:
Table of Contents

Advertisement

(5) Some Master devices, such as the Mitsubishi A1SJ71PB92D
Programmable Controller will require that this data be sent to the
inverter in a "byte-swapped" configuration. In this case, the position of
the high-order byte and the low-order byte are switched in the data
string.
The FR-A5NP communications buffer memory map is illustrated in the
following tables:
Parameter Id
Bit No:
15
Parameter Index
Bit No:
15
Parameter Value
Bit No:
15
Parameter Value HIGH
Parameter Value LOW
Process Data
Bit No:
15
Command Count
Reserved
AK
: Task or Response Id
SPM : Toggle bit for processing the parameter change report. (Not
supported, should always be zero.)
PNU : Parameter number
(6) These 6 words (described in following subsections) are how the
network master and slave (the option unit) communicate via the
PROFIBUS-DP protocol. It is through this addressing scheme that the
sender indicates which data word within the drive is being accessed
and what that access is.
(7) This option unit does not support any other manufacturer-specific
messages/parameters.
INVERTER PROFIBUS DATA WORD DEFINITION
12
11
AK
SPM
8 7
Index
8 7
Status
(HIW)
17
(PKE)
10
PNU
(IND)
Value (PP)
(PWE)
(PWE1)
(PWE2)
(ZSW1)
Word #1
0
Word #2
0
0
Word #3
Word #4
0
Word #5
Word #6