4. TROUBLE SHOOTING
4.4.2 PAM INPUT Part(Locosto Output)
CHECKING FLOW
Check Control
Signals
Signals are
Normal ?
Yes
PAM Control Signal
is OK.
See next page to
check
ASM & Mobile SW
Circuit.
VBAT
ECCH0003002
C2012JF1A106ZT
C407
C408
C405
C406
C409
0.01u
0.01u
0.01u
39p
10u
L411
15
DCS_PCS_OUT
3.3nH
C415
C417
11
EGSM_OUT
0.5p
1p
SKY77318
19
RSVD_GND
21
P_GND
L410
C419
2.7nH
C421
DNI
0.5p
< PAM INPUT Circuit>
LGE Internal Use Only
No
Check
Locosto(U102)
R400
15K
C400
close to DBB
68p
3
DCS_PCS_IN
4
U400
EGSM_IN
18
ENABLE
1
BS
C422
C423
0.5p
27p
-38-
SW400
< PAM INPUT Placement>
TX_RAMP
L400
TXHB
3.3nH
C402
C403
VDDRF1
L401
1.5p
1.5p
1nH
C410
15p
C412
180p
L403
18nH
C413
R403
TXLB
10
L404
47p
C418
C414
DNI
10nH
1.5p
R404
47
PA_EN
R405
47
PA_BAND
- 42 -
Copyright © 2009 LG Electronics. Inc. All right reserved.
U102
X101
FL400
U400
High Band
Type 5dB
(3 ~ 7dB)
Low Band
Type 5dB
(3 ~ 7dB)
Only for training and service purposes