5
Disconnect the Anode Cable
WARNING:
Before disconnect the anode cable, turn off the power,
unplug the AC plug and let the unit discharge for more than 1 minut.
5
6
MEASURING METHOD
Disconnect the FBT anode cable as shown below.
Measure at the point where the cable enters the FBT.
Caution : Take extra precaution when
measuring the voltage. High voltage are also
present in surrounding circuit boards. (CRT
assy, POWER SUPPLY assy)
Pull straight up
Cover
Pull straight up
Rear View
FBT
DEFLECTION SERVICE Assy
PRO-730HDI
6
7
SERVICEMAN WARNING
Before removing the anode cable, turn off
the power, unplug the AC plug and let the
unit discharge for more than 1 minut.
Anode Cable
FBT
Note :
When reconnecting the cable, proceed in the
reverse order. After reconnecting, tug on the
cable to check that it is secure.
7
8
A
B
C
D
E
F
123
8