HP T2touch PANEL Service Manual page 63

Table of Contents

Advertisement

MACHINE IS NOT DRYING
Is the Filter and
Condenser
Clean?
NO
Is compressor
overload
protector open
circuit?
NO
Is connection of
compressor
connector
correct?
YES
Are the measured
resistance values
​ ​ t hrough the Comp.
NTC Correct
?
YES
Are the measured
resistance values
​ ​ t hrough the
compressor connector
correct?
YES
Is drum rotating
CW
YES
Is machine
power correct?
YES
User should be informed about
the machine.
HP T2touch PANEL
SERVICE MANUAL
NO
Clean Filter and / or Condenser
YES
Wait temperature of the compressor surface
decrease room temperature and check again.
Make Electrical Connection
NO
NO
Change compressor NTC
NO
Change the compressor
NO
Check the drum is not rotating alg.
Is the compressor
NO
cable transmitted the
current to e. card ?
EVET
Check the compressor gas
CUSTOMER
SUPPORT
HAYIR
Change the cable tree

Advertisement

Table of Contents
loading