ABB HT609106 Operation Manual page 103

Table of Contents

Advertisement

Operation Manual / TPS48-D/E.. - TPS61-D/E..
9 Taking out of operation / 9.1 Shutting down the turbocharger
© Copyright 2020 . All rights reserved.
Cover plate drawing
The cover is not included in the scope of delivery of ABB and must be
manufactured by the operator according to the following drawing.
Material: Common structural steel, in compliance with DIN EN 10025-2
Product
B1
±0.5
TPS48
65.7
TPS52
79.6
TPS57
98.2
TPS61
116.8
Product
B7
TPS48
35.7
TPS52
39.6
TPS57
48.2
TPS61
56.8
Dimensions in [mm]
HZTL2410_EN
B2
B3
±0.2
60
130
11.7
78
155
14.2
100
190
17.2
120
226
20.5
ØD1
ØD1*
ØD2
±0.2
±0.2
222.7
227.7
265.7
271.7
325.7
332.5
387.7
395.9
B4
B5
B6
1.5
150
1.5
180
2
220
2.4
260
R1
M
17
≤ 105
M8
21
≤ 125
M8
21
≤ 153
M10
≤ 182
25
M10
Rev.F