Product Specifications; Electrical & Mechanical Properties - LG N1T-V Series Installation Manual

Pv solar module
Table of Contents

Advertisement

PRODUCT SPECIFICATIONS

N-TYPE
Rated electrical characteristic except power rating within -0/+3 percent are within 5 percent of measured.
Values at Standard Test Condition(STC) : Irradiance 1000W/m
Module
Pmax
Model Name
Series
at STC
W
LG310N1T-V5
310
315
LG315N1T-V5
LG320N1T-V5
320
LG325N1T-V5
325
LG330N1T-V5
330
LG335N1T-V5
335
LG340N1T-V5
340
LG410N2T-V5
385
LG415N2T-V5
390
LG420N2T-V5
395
LG425N2T-V5
400
LG430N2T-V5
405
LG435N2T-V5
410
Note) MC4 formal name : PV-KST4 / 6II-UR, PV-KBT4 / 6II-UR
→ Plus (+) Connector : Male MC4 coupler (PV-KBT4/6II-UR)
→ Negative (-) Connector : Female MC4 coupler (PV-KST4/6II-UR)
Note) The Typical change in module efficiency at 200W/m in relation to 1000W/m is -2.5% (Min. -3.0%)
◇ Female and male cable couplers ◇
Male cable coupler
Female cable coupler
Electrical Properties(NMOT*)
Model
Maximum Power (Pmax)
[W]
MPP Voltage (Vmpp)
[V]
MPP Current (Impp)
[A]
Open Circuit Voltage (Voc)
[V]
Short Circuit Current (Isc)
[A]
* NMOT (Nominal Module Operating Temperature) : Irradiance 800W/m , ambient temperature 20℃, wind speed 1m/s
Temperature Characteristics
Model
NMOT
[ °C ]
Pmax
[%/°C]
Voc
[%/°C]
Isc
[%/°C]
Electrical Properties
Power
Voc at
Isc at
Vmpp
Tolerance
STC
STC
at STC
%
V
A
0~3%
39.7
10.14
32.6
0~3%
39.7
10.18
32.9
0~3%
39.8
10.22
33.2
0~3%
39.8
10.26
33.5
0~3%
39.9
10.30
33.8
0~3%
40.0
10.34
34.1
0~3%
40.1
10.38
34.4
0~3%
49.4
10.10
40.3
0~3%
49.5
10.14
40.7
0~3%
49.6
10.18
41.1
0~3%
49.7
10.22
41.5
0~3%
49.8
10.26
41.9
0~3%
49.9
10.30
42.3
2
Model
MC4
※ See more information >>
LGXXXN1T-V5
310
315
320
325
232
236
240
243
30.6
30.9
31.2
31.4
7.60
7.64
7.70
7.74
37.3
37.3
37.4
37.4
8.15
8.18
8.21
8.24
2
LGXXXN1T-V5
LGXXXN2T-V5
42 ± 3
-0.36
-0.27
0.03
2
, Cell temp. 25℃, 1.5AM
Max.
Max.
Impp at
No. of
Series
System
STC
module
Fuse
Voltage
in series
Rating
V
A
A
9.52
19
20
9.58
19
20
9.65
19
20
9.70
19
20
9.77
19
20
9.83
19
20
9.89
19
20
9.56
16
20
9.59
16
20
9.62
16
20
9.65
16
20
9.68
16
20
9.71
16
20
"Max. No. of modules in series" is considering 125% of Voc. Actual number of connections
should be selected according to the installation site conditions and local code.
2
Cable Cross Section
Ø A (Cable outer diameter)
4mm²
12AWG
http://www.multi-contact.com/
330
335
340
410
247
251
255
289
31.7
32.0
32.3
37.9
7.80
7.84
7.89
7.62
37.5
37.6
37.7
46.6
8.28
8.31
8.34
8.12
42 ± 3
-0.36
-0.26
0.03
Mechanical Properties
Max.
Connector Length Width Height Weight
V
mm
mm
1000
1686
1016
MC4
1000
1686
1016
MC4
1000
MC4
1686
1016
1000
1686
1016
MC4
1000
1686
1016
MC4
1000
1686
1016
MC4
1000
1686
1016
MC4
1000
2024
1024
MC4
1000
2024
1024
MC4
1000
2024
1024
MC4
1000
2024
1024
MC4
1000
2024
1024
MC4
1000
2024
1024
MC4
Rated current
5.5 ~ 9mm
30A
LGXXXN2T-V5
415
420
425
430
292
296
300
304
38.2
38.6
39.0
39.4
7.65
7.67
7.69
7.72
46.7
46.8
46.9
47.0
8.15
8.19
8.22
8.25
mm
kg
40
17.1
40
17.1
40
17.1
40
17.1
40
17.1
40
17.1
40
17.1
40
20.3
40
20.3
40
20.3
40
20.3
40
20.3
40
20.3
435
308
39.8
7.74
47.1
8.28
11