Safety Precautions
To avoid fire, electric leakage, electric shock or
abnormal operation
If the power cord is damaged, it must be replaced by the
manufacturer, its service agent or a qualified person in order to
avoid hazards.
Electrical work must be performed by a legally certified electrician.
Before installation, make sure to turn off the circuit breaker.
Install a 230-240 V / 13 A dedicated single-phase circuit with an
earth leakage circuit breaker for the power supply to avoid
abnormal overheating of the electric wire.
This appliance must be properly earthed following the electric laws.
The earth line must not be connected to a gas pipe, water pipe,
earth of lightning rod or telephone.
The power cord must be correctly connected to ensure the integrity
of the connection.
Do not step on the appliance, or drop heavy items on top of it.
Do not disassemble, repair or modify the appliance.
(Ex. Disassembling the top plate)
To avoid fire, deformation or discolouration
Use a heat resistant material for the countertop.
( Heat resistance equal to or exceeding that of "laminated
thermosetting high-pressure decorative sheets")
Do not use a varnished material for the countertop.
26
WARNING
CAUTION
Dimensions
Top view
742
Exhaust vent
400
229
181
380
Intake vent (on the undersurface)
Side view
6
18
364
Intake vent
Approx. 1.5 m
Related Dimensions (Built-in)
Countertop cutout
368
Cabinet front
Cabinet
Countertop with bulge in front
More than 25 mm
Bulge
for flat part
More
than 6*
Do not install unless the
condition above is met.
*The clearance for the intake has to be more than 40 cm².
If a partition board without an intake part has been set
Countertop
Partition board
(unit: mm)
Front view
KY-C227E model
705
18.5
KY-A227E model
705
18.5
+
R3
1
+3
Template provided
−0
with the appliance
710
+3
−0
(12 - 30)
More than 470
+3
368
(Depth of mounting hole)
−0
Intake
Flow from intake to exhaust
Exhaust vent
Cut
Make holes.
(More than 100)
(Approx. Ø 100×8)
or
101
107
87
93
27