en | Optical alignment
1. Turn off the transmitter Function switch 6.
2. Follow steps 2 and 3 as listed in the Level LED – alignment of the Upper Beam procedure. If
LED turns off, alignment is complete.
Figure 8.2: Level LED
Callout ﹘ Description
1 ー Receiver LED console
Notice!
Turn on Function switches 1 and 2 of the transmitter after finishing the alignment to verify the
monitor LEDs light up once every 3 seconds.
8.3

Volt meter alignment

Insert the volt meter leads into the alignment check terminals of the receiver to check voltage.
If the value is 3.0 V or higher, the adjustment is completed. If less than 3.0 V, adjust the
receiver and transmitter until 3.0 V is obtained.
Notice!
In an ideal environment, the voltage is 3.0 VDC or above.
1
Figure 8.3: Volt meter alignment
Callout ﹘ Description
1 ー Alignment check terminals