en
"Calc'n clean"
Cleaning the Boiler
To extend the life of your steam generator and
to avoid any build up of scale, it is essential that
you rinse out the boiler after several hours of use
(approximately after 50 hours). If the water is
hard, increase the frequency.
Do not use descaling agents for rinsing out the
boiler, as they could damage it.
1. Check that the appliance is cold and
unplugged for more than 2 hours, and that
the water tank (1) is empty.
2. Place your appliance on the edge of your
kitchen sink, so that any residual water in the
water tank is directed into the sink.
3. Remove the plastic cover located on the
bottom of the appliance by turning it to the
position.
������������
������
��
* model dependent

4. Unscrew the boiler drainage plug using a
coin.
5. Holding your steam generator in an upside
down position, and using a jug, fill the boiler
(in the base unit) with 1/4 litre of water
6. Shake the base unit for a few moments and
then empty it completely over a sink or bucket.
To obtain the best result, we recommend that
this operation is done twice.
Important: before closing, make sure no
water remains in the boiler.
7. Replace and tighten up the boiler drainage
plug with a coin.
8. Insert and close the plastic cover by turning it
to the
position.
�������
��