Mitsubishi Electric PMCR-50VHA-200D KIT Installation Manual page 9

Flow temp. controller 2br cased
Table of Contents

Advertisement

3. System
CN401
(WH)
CN1A
(WH)
INPUT
Remote controller
Thermistor
<Fig. 4.1.3>
Wiring for FTC2BR
<1 phase>
Earth
Power
leakage
circuit
supply
breaker
~/N
*1.
230V
50Hz
Wiring
circuit
Earth
Power
breaker
leakage
supply
or
circuit
~/N
Isolating
breaker
230V
switch
50Hz
<3 phase>
Earth
Power
leakage
supply
circuit
~/N
breaker
230V
*1
50Hz
Wiring
Power
Earth
circuit
supply
leakage
breaker
3N~
circuit
or
400V
breaker
Isolating
50Hz
switch
<Fig. 4.1.4>
Electrical connections 1 phase/3 phase
CNS2
(RD)
To outdoor unit
OUTPUT
Power cables
Wiring
FTC2BR
circuit
breaker
L
or
Isolating
N
switch
Outdoor unit
To control
board
S1
L
S1
S2
S2
N
S3
S3
TB6
Wiring
FTC2BR
circuit
breaker
L
or
Isolating
N
switch
Outdoor unit
L1
To control
L2
board
S1
S1
L3
S2
S2
N
S3
S3
TB6
Option 2: FTC2BR powered by independent source
If FTC2BR and outdoor units have separate power supplies, the following
requirements MUST carried out.
• Remove the short circuited connector CNS2.
• Turn on the outdoor unit before the FTC2BR.
• Outdoor unit DIP switch settings changed to SW8-3 ON.
• Power by independent source is not available for particular models of outdoor unit
model.
For more detail, refer to the connecting outdoor unit installation manual.
Notes:
1. Do not run the low voltage cables through a slot that the high voltage ca-
bles go through.
2. Do not bundle power cables together with other cables.
3. Bundle cables as Fig. 4.1.3 by using clamps.
*1. A breaker with at least 3.0 mm contact separation in each pole shall be provided.
Use earth leakage breaker (NV).
The breaker shall be provided to ensure disconnection of all active phase
conductors of the supply.
*2. Max. 45 m
If 2.5 mm² used, Max. 50 m
If 2.5 mm² used and S3 separated, Max. 80 m
*3. The values given in the table above are not always measured against the ground
value.
Notes:
1. Wiring size must comply with the applicable local and national codes.
2. FTC2BR/outdoor unit connecting cords shall not be lighter than
polychloroprene sheathed flexible cord. (Design 60245 IEC 57)
FTC2BR unit power supply cords shall not be lighter than
polychloroprene sheathed flexible cord. (Design 60227 IEC 53)
3. Install an earth longer than other cables.
FTC2BR power supply
FTC2BR input capacity
FTC2BR - power supply
FTC2BR - power supply earth
FTC2BR - Outdoor unit *2
FTC2BR - Outdoor unit earth
FTC2BR L-N *3
FTC2BR - Outdoor unit S1 - S2 *3
FTC2BR - Outdoor unit S2 - S3 *3
~/N 230 V 50 Hz
16A
2×Min. 1.5
1×Min. 1.5
2×Min. 0.3

230V AC

24V DC
en
EN-9