PHILIPS 4000 and 3000
Level 3 (Brewing unit)
Start condition: NO BU, Drag drawer, door
Closed and No Water sensor
If the Dreg drawer is not inserted or the Service door is
not closed the BU test cannot be performed. If these 2
inputs are not in the right position, Led Dreg drawer full
will be RED
Action by user
When the BU reaches the work position the Led NoBeans
is switched on
ERROR: Led NoBeans remains off, Check the work mi-
croswitch (broken?), the BU motor (blocked?) and the wi-
ring (JP16).
ERROR: led GenAlarm Switch ON; the absorbed current
is much more 300mA (with BU) or 200mA (without BU)
check the BU and the motor
Action by user
When the BU reaches the home position the Led NoBeans
is switched on
ERROR: Led NoBeans remains off, Check the work mi-
croswitch (broken?), the BU motor (blocked?) and the wi-
ring (JP16).
ERROR: led GenAlarm Switch ON; the absorbed current
is much more 300mA (with BU) or 200mA (without BU)
check the BU and the motor
Finish condition: With BU, Drag Drawer,
door closed
Level 4 (Pump)
Start condition: BU not inserted, Drag drawer and
service door closed, no water sensor
If the Dreg drawer is not inserted or the Service door is
not closed the EV cannot be opened and test cannot be
performed. If these 2 inputs are not in the right position,
Led Dreg drawer full will be RED
Press BUTTON Stand-By to move to the next screen
Press the Espresso button to move BU to work
Press the Coffee button to move BU to home
Press BUTTON Stand-By to move to the next screen
LED INDICATION
Led
Led
NoBeans
NoWater
OFF
OFF
NA
NA
LED INDICATION
Led
Led
NoBeans
NoWater
ON
NA
NA
NA
NA
NA
LED INDICATION
Led
Led
NoBeans
NoWater
ON
NA
NA
NA
NA
NA
LED INDICATION
Led
Led
NoBeans
NoWater
OFF
OFF
LED INDICATION
Led
Led
NoBeans
NoWater
OFF
OFF
NA
NA
05 SERVICE MODE
Led
Led Dreg
GenAlarm
drawer full
OFF
OFF
ON
NA
Led
Led Dreg
GenAlarm
drawer full
NA
NA
NA
NA
ON
NA
Led
Led Dreg
GenAlarm
drawer full
NA
NA
NA
NA
ON
NA
Led
Led Dreg
GenAlarm
drawer full
OFF
OFF
Led
Led Dreg
GenAlarm
drawer full
OFF
OFF
NA
ON