Connecting the ducts
6
・Use a joiner to connect two ducts together.
・Be sure to match the polarities of the ducts
   and the joiner and secure by tightening the
set screws.
Duct
Set screw
Duct
Long
Short
Joiner
Caution
During construction, Do not give a shock, 
such as dropping on a product, or hitting.
It may be damaged.
Combine the tip of a duct and connect certainly.
Connect a straightly both of the duct
Securely fasten the set screws. (Proper torque: 
0.98 N ・ m〜1.32 N ・ m)
Doing so may result in an electric shock or a fire.
When cutting the ducts, use a metal 
hacksaw(hand type)and cut with the opening in 
the duct facing downward as shown in the 
figure.
If a power saw is used, the insulation cladding or 
ground terminals could be scraped or burned.
After cutting, if the ground terminal protrudes 
slightly, correct it.
Remove any cutting chips or burrs from the cut 
surface.
Doing so may result in an electric shock or a fire.
Attaching the end cap
8
・Fit the cap onto the end of the duct and secure it by tightening the set screw.
An end cap must be attached onto the end of the duct.
 Doing so may result in an electric shock.
Securely fasten the setscrew.(Torque the setscrew to not 
less than 0.98 N ・ m〜1.32 N ・ m)
Joiner
Set screw
Polarity indication
(ground side)
(Cutting direction)
Ground terminal
Duct
Opening
Caution
Installing the feed-in cap
7
■Connecting the ducts
●Fit the feed-in cap into the duct and tighten 
   the set screw to secure it.
Duct 
the peep hole
Set screw
■Procedure for providing knock-out part
①For cables not larger than VVF of 2 ㎟ in 
size with three cores or less, remove the 
shaded area.
②For cables not larger than VCT of 3.5 ㎟ in 
size with three cores or  less, remove the 
shaded area.
●Deburr the cut surface using a Cable Knife.
■Connection of power supply, remove about electric wire
●Strip the ends of the electrical wires in accordance with the 
stripping gauge shown on the inside of the cover, and then 
insert the electrical wires until they are visible in the peep hole.
●To disconnect the electrical wires, pull them out while using 
a screwdriver or your finger to press the connection release 
button.
Caution
During construction, Do not give a shock, such 
as dropping on a product, or hitting.
It may be damaged
Connect the feed-in cap and the duct linearly.
Securely fasten the set screws. (Proper torque: 
0.98 N ・ m〜1.32 N ・ m)
Using the single-wire cable is 1.6 mm or 2 mm,
Be sure to use an insulated pin 
terminal(Insertion length: It is longer than 
15mm and is less than 21mm.) when use a 
stranded-conductor cable.
Use a triplex cable and tighten the coil to the 
ground terminal to connect one cable. 
(Proper torque: 1.2 N ・ m〜 1.5 N ・ m) 
Doing so will result in an electric shock, a fire.
After wire connection, Bind the cable with wire 
ties, etc. not to apply tension to the terminal.
Doing so will result in a fire.
Duct
7
Holding part
Ground terminal
of a fastning band
Electric wire
loading slot
Connection release button
Polarity
indication
Duct
cover
Duct
cover
End cap
Set screw