Removal and installation
Fixing clamping nuts
Figure 13: CE foot contact surface
Tighten clamping nuts on compressor end (CE) (see Tightening the clamping nut [➙ 17]).
Figure 14: TE foot: Handling of cup spring contact surface / foot contact surface
Coat the contact surface (F) for the cup springs (X) (see Table 3) at the foot of the turbine
end (TE) with high-temperature grease.
Tighten clamping nuts on turbine end (TE) (see Tightening the clamping nut [➙ 17]).