Frames And Fixtures - Electrolux SMART Installation Instructions Manual

Boiling pans with tilting height 600mm
Hide thumbs Also See for SMART:
Table of Contents

Advertisement

12.3 Frames and fixtures

Foundation or mounting frames and fixtures are
supplied disassembled. These should be as-
sembled according to the following instructions.
NOTE
Please follow these instructions
• Check that the dimensions of the supplied
frames and number marking on the various
fixtures agree with the information in this in-
stallation instruction.
• Check that: measure r, between the wall and
the mounting frames, is correct to an accur-
acy of +/- 2 mm. (See Fig. 4, 7 and 10)
Frames D/E and fixtures B are screwed together
with the enclosed screws m6S 12x20 (see Fig.
4A-B).
Angle between fixtures and frames is 90° (check
with set square), (see Fig. 3).
r: For measure see subsequent pages
G: Front edge of frame.
foundation frame
model
PNC
Left Sm6B,
928031
Sm6V, Sm6P
Left SV6I, SP6I
928032
Right 50-100L
928032
Right 150-300L
928033
Fig. 3
22
INSTALLATION INSTRUCTIONS | SmART LINE BOILINg PAN
12.3.1
The foundation frames D are cast:
• So that level A is 5-10 mm above the highest
point of the finished floor
• Horizontal in all directions
• The last part of the frame must be filled with
compound or similar up to Level A
• Expander bolt C, chemical anchor or equival-
ent m10, (not supplied)
• min. extraction force 500 kp = 4900 N
mounting frame
12.3.2
PNC
928034
928035
928035
928036
The mounting frames E are secured:
• With expander bolt C, chemical anchor or
equivalent m 10, (not supplied)
min. extraction force 500 kp = 4900 N
• NOTE: The frames are at the same level
• Horizontal in all directions
• The frame must be filled with compound or
similar up to Level A
DOC N° ST0 9183-02
Foundation frames
Fig. 4A
mounting frames
Fig. 4B