Download Print this page

Flow Of Functional Operation - JVC NX-HD10 Service Manual

Compact component hdd system
Hide thumbs Also See for NX-HD10:

Advertisement

Flow of functional operation until TOC read (CD)
Power ON
Tracking error waveform at TOC reading
Approx.3sec
pin 20 of
IC601(TE)
Approx
1.8V
VREF
Tracking
Tracking
servo
servo
on states
off states
Disc states
to rotate
Automatic measurement
of TE amplitude and
automatic tuning of
TE balance
Play Key
Automatic tuning of
Automatic measurement of
Focus S-curve amplitude
Automatic measurement of
Tracking error amplitude
Disc to be
braked to stop
Automatic tuning of
TOC reading
finishes
Tracking error balance
500mv/div
2ms/div
Fig.1
Slider turns REST
SW ON.
Automatic tuning
of TE offset
Laser ON
Detection of disc
Focus offset
Disc is rotated
Focus servo ON
(Tracking servo ON)
Automatic tuning of
Focus error balance
Automatic tuning of
Focus error gain
Automatic tuning of
Tracking error gain
TOC reading
Play a disc
Check Point
Confirm that the voltage at the pin32
of IC251 is "H"\"L"\"H".
Confirm that the Focus error
S-cuve signal at the pin28 of
IC651 is approx.2Vp-p
Confirm that the signal from
pin24 IC651(R808) is 0V as
a accelerated pulse during
approx.400ms.
Confirm the waveform of
the Tracking error signal.
at the pin 20 of IC601 (R604)
(See fig-1)
Confirm the eys-pattern
at the lead of TP1
NX-HD10
1-21

Advertisement

loading

This manual is also suitable for:

Sp-nxhd10Ca-nxhd10