Rom & Ssp Diagnostics; Standard Rom Check; Service Rom Check; Ssp Check - Sharp UP-3300 Service Manual

Pos terminal
Hide thumbs Also See for UP-3300:
Table of Contents

Advertisement

2 Display
UP-P02MB2 Check
Extended RAM size : 2048KB
Error Address
xxxxxxH
Write Data
xxxxH
Read Data
xxxxH
The error address and the bit are displayed only when the error
occurs. (If the error does not occur, the error address will not be
displayed.)
3 Terminating procedure
After completion of check, press the Touch panel.
3-3. ROM & SSP Diagnostics
The standard ROM and the service ROM are checked. The SSP
circuit is also checked.
The following menu is displayed. Press the thouch key for of the
operation you want to execute to execute individual Diag programs.
Pressing the CANCEL key returns the screen to the Diag MAIN
menu.
ROM & SSP Diagnostics

Standard ROM Check

Service ROM Check

SSP Check

1) Standard ROM Check
1 Check contents
The standard ROM area (200000H ∼ 3FFFFFH) is added in the
unit of byte. If the lower two digits of the result is 20H, it is normal.
The ROM version and the model name code which are stored in
address 31FFE0H ∼ 31FFFFH where the ROM version and the
check sum correction data stored are displayed. The format of
data (ASCII) to be stored is as follows:
31FFE0H ∼ 31FFEFH: Model name code (example: UP-3300,
Display is made up to 00H of data.)
31FFF0H ∼ 31FFF9H: 27801R****(****=PROGRAM VERSION)
31FFFAH ∼ 31FFFBH: BLOCK NO. ("20" ∼ "3F")
31FFFCH: TERMINATOR ("=")
31FFFDH ∼ 31FFFEH: BLOCK VERSION (example "00")
31FFFFH: CHECK SUM CORRECTION DATA
The flash ROM used as the standard ROM has rewriting block of
64KB as the unit. To control the version in each block, the com-
position is the same as the above 31FFF0H or later and arranged
in each 64KByte. At that time, correction is made so that the sum
of each block becomes 01H, and the total of 2MByte is 20H.
The FLASH write MASTER EPROM has changed from 8 Mbits to
2 chips so that the program version indication can be managed by
each chip. The program version stored in the blocks of 21H and
31H is displayed.
The program version of the IPL is displayed so that 0PAGE where
the IPL is stored is individually controlled.
PASS!!(or ERROR!!)
Cancel
2 Display
Standard ROM Sum Check
IPL PROGRAM Version
**
APL PROGRAM Version
27801R****
27801R****
BLOCK Version
20=** 21=** 22=** 23=** 24=** 25=** 26=** 27=**
28=** 29=** 2A=** 2B=** 2C=** 2D=** 2E=** 2F=**
30=** 31=** 32=** 33=** 34=** 35=** 36=** 37=**
38=** 39=** 3A=** 3B=** 3C=** 3D=** 3E=** 3F=**
3 Terminating procedure
After displaying the check result, press the Touch panel to ter-
minate the check.
2) SERVICE ROM Check
Note: This check should only be performed will be using the service
ROM.
1 Check content
The standard ROM (EPROM × 2 Chip) area (D00000H ~ EF-
FFFFH) is added in the unit of byte. If the lower two digits of the
result is 10H, it is normal. The ROM version and the model name
code which are stored in address D1FFE0H ~ D1FFFFH where
the ROM version and the check sum correction data are stored
are displayed. The format of data (ASCII) to be stored is as fol-
lows:
D1FFE0H ∼ D1FFEFH: Model name code (example: UP-3300.
Display is made up to 00H of data.)
D1FFF0H ∼ D1FFF9H: 27801R****(****=PROGRAM VERSION)
D1FFFAH ∼ D1FFFBH: BLOCK NO. ("20" ∼ "2F")
D1FFFCH: TERMINATOR ("=")
D1FFFDH ∼ D1FFFEH: BLOCK VERSION (example "00")
D1FFFFH: CHECK SUM CORRECTION DATA
This SERVICE ROM allows to write into the FLASH ROM when
re-execution is impossible because of an abnormality during
rewriting into the FLASH ROM. The composition is the same as
the standard ROM.
The program version of the IPL is displayed so that 0PAGE where
the IPL is stored is individually controlled.
2 Display
Service ROM Sum Check 1 : PASS!!(or ERROR!!)
Service ROM Sum Check 2 : PASS!!(or ERROR!!)
IPL PROGRAM Version
**
APL PROGRAM Version
27801R****
27801R****
BLOCK Version
20=** 21=** 22=** 23=** 24=** 25=** 26=** 27=**
28=** 29=** 2A=** 2B=** 2C=** 2D=** 2E=** 2F=**
:
3 Terminating procedure
After displaying the check result, press the Touch panel to ter-
minate the check.
3) SSP Check
1 Check content
By starting this check program, the SSP setting for checking is
automatically performed and the SSP check is executed and the
result is displayed.
6 – 3
: PASS!!(or ERROR!!)
← Display the version.
UP-3300
UP-3300
← Display the version.
UP-3300
UP-3300

Advertisement

Table of Contents
loading

Table of Contents