3. OPERATION PROCEDURE [How to Use the Digital Monitor]
(2) How to Display Shutdown History
Discharge pressure display
SELECT/WIDE
1
Press 8 times.
SELECT/WIDE
1
Press once to go to
the next item.
2
Press once to go to
the previous item.
RESET
Return to discharge
pressure display.
IMPORTANT
Air-Cooled
For the shutdown history of fan inverter,only the most
recent shutdown will be recorded. Shutdown history is
displayed in shutdown codes.
(
4.1 (a)(b))
(3) How to Display Various Settings (Perform operation only when confirmation is
necessary.)
Dis. pres. display
SELECT/WIDE
1
Press 16 times.
SELECT/WIDE
1
Press once to go to
the next item.
2
Press once to go to
the previous item.
RESET
Return to discharge
pressure display.
※ No.3 and 7 are not in use for Vtype.
26
[Latest shutdown]
[Previous shutdown]
XX : Shutdown code
[Oldest shutdown]
History consists of 6 data items.
Main motor controller
shutdown history
Fan inverter
shutdown history (air-cooled type only)
Water-cooled type - Not used (display only)
To display of various settings
No.0 :
Control status
A :
Capacity Ctrl system
No.1 :
Cut-out pressure 1
100
:
100 psi
No.2 :
Cut-in pressure 1
085
:
85 psi
No.3 :
Pres. diff. 1
007
:
7 psi
No.4 : ECOMODE
Cycle time
30 second
No.5 :
Cut-out pressure 2
100
:
100 psi
No.6 :
Cut-in pressure 2
085
:
85 psi
No.7 :
Pres. diff. 2
007
:
7 psi
No.8 :
IPI setting
000
:
Disabled
No.9 :
Compressor No.
001
:
No.1
Use the following procedure to display shutdown history.
Press the SELECT/WIDE button 8 times. "E0." is the
displayed with the shutdown code (
most recent shutdown. (The display automatically changes to
"E.0" when a shutdown or alarm occurs.)
② Press the SELECT/WIDE button. "E1." is displayed along
with a shutdown code. "1" indicates a shutdown that
occurred previously. Six items of data (0 to 5) are recorded.
"E5" indicates the oldest shutdown.
Air-Cooled
③ Press the SELECT/WIDE button. "E7." indicates a
shutdown history of the fan inverter.
④ Press the RESET button. The screen is return to the
operation status.
IMPORTANT
If the shutdown code "XX" is "
there is no shutdown history. Also, when anything other
than shutdown history is displayed without shutdown
resetting, the display is return to the latest shutdown
history in 3 minutes.
IMPORTANT
For the shutdown history of controller, only the most
recent shutdown is recorded. Shutdown history is
displayed in shutdown codes. (
Use the following procedure to display capacity control type
and pressure setting values for confirmation.
① Press the SELECT/WIDE button 16 times. "0.A * *" is
displayed on the screen. The content of "* *" varies
depending on specifications. "A" may be "L" or "U"
depending on capacity control specifications.
② Consists of items 0 - 9. Pressure setting status and optional
pressure setting 2 can be confirmed each time the
SELECT/WIDE button is pressed.
③ Press the RESET button. The screen is return to the usual
discharge pressure display.
IMPORTANT
Symbols displayed at No.0 and corresponding capacity
control type
A : AUTO function setting
L : Fixed speed type setting (INTE: load/unload
operation)
U : Vtype setting (AUTO function canceled
(
3.3.5
and 8.4)
4.1) "0" indicates the
," it indicates that
4.1 (a)(b))