Fire Safety CERBERUS PYROTRONICS MODEL VDT Interface for the CERBERUS PYROTRONICS MXL Operation and Installation Manual Siemens Building Technologies, Inc. Siemens Building Technologies, Ltd. 8 Fernwood Road 2 Kenview Boulevard Florham Park, New Jersey 07932 Brampton, Ontario L6T 5E4 CN P/N 315-091734-9 Technical Manuals Online! - http://www.tech-man.com...
Page 2
Table of Contents Page INTRODUCTION ......................1 OPERATION ........................1 CSG-M Requirements .................... 1 Acknowledgment and Audible Commands ............1 Acknowledge Alarm................... 1 Acknowledge Supervisory ................. 1 Acknowledge Trouble ..................1 Acknowledge Security ..................1 Silence/Unsilence Audibles ................2 Reset the MXL ....................2 Entering the LIST Commands from the VDT ............
Table of Contents (continued) Page Control Air Sampling Airflow Trip Points ............7 Control Percent/Ft Sensitivity ................7 Control Percent/Ft Pre-Alarm ................7 Control ASD Application ..................7 Using the TEST Command from the VDT ............8 Change Time ..................... 8 Power Report ....................
Page 4
INTRODUCTION CERBERUS PYROTRONICS OPERATION MXL command: (text typed) NOTE: AAL - Acknowledge Alarm (AA) ASP - Acknowledge Supervisory ATR - Acknowledge Trouble (AT) ASC - Acknowledge Security When Block Acknowledge is selected in the CSG-M, NOTE: NOTE: NOTE: Technical Manuals Online! - http://www.tech-man.com firealarmresources.com...
Page 5
When Individual Acknowledge is selected in LAL - List Alarms (LA) the CSG-M, SUA - Silence/Unsilence Audibles (See List Alarm MXL/MXLV Manual, CRS - Reset the MXL (CR) LSP - List Supervisory List Supervisory MXL/ MXLV Manual, LTR - List Trouble (LT) m, m-d, List Trouble MXL/MXLV Manual,...
Page 6
LMT - List Module Type List Sensitivity Settings MXL/MXLV Manual, LAV m - List Analog (analog2) Voltage (LDO) List Module MXL/MXLV Manual, LDT m List Device Type List Voltages MXL/MXLV Manual, List LTV m List Threshold Voltage Device MXL/MXLV Manual, LMS m - List Messages (LM) List Voltages MXL/MXLV Manual,...
Page 7
LCV m - List XLD-1 Calibration Voltage LAP m - List Air Sampling Airflow Percent List XLD-1 Calibration Voltage LAT m - List Air Sampling Alarm Trip Points MXL/MXLV Manual, LIV m - List XLD-1 ID Voltage LFT m - List Air Sampling Airflow Trip Points List XLD-1 ID Voltage MXL/MXLV Manual,...
Page 8
LPA m - List Percent/Ft Analog LCM - List Modules in Commissioning Mode Listing of Modules in Commissioning Mode: 1-ALD: ON 2-ALD: ON 3-FS Interface (NIM): ON 4-CRM4: ON LAS m - List ASD Applications Listing of Modules in Commissioning Mode: NO ENTRIES: only default values found LON xxxx - Log On (Enter password) LOD - List Disarmed Output State...
Page 9
m-d x COP m-d x y - Change Output Point (CO) Device ID mismatch m-d x m-d x CIP m-d x - Change (Arm/disarm) Input Point (CO) CAT - Control Air Sampling Alarm Trip Points Technical Manuals Online! - http://www.tech-man.com firealarmresources.com...
HAL hh:mm:ss mm-dd-yyyy - Alarm History CTD hh:mm:ss nn-dd-yyyy - Change Time (CT) HSP hh:mm:ss mm-dd-yyy - Supervisory History HTR hh:mm:ss mm-dd-yyy - Trouble History HSC hh:mm:ss mm-dd-yyyy - Security History yyyy NOTE: MUST HAE hh:mm:ss mm-dd-yyyy - All Event History LMP - Annunciator Lamp Test PWR m Power Report LCD - Annunciator Display Test...
DEV m-d x - Device LED NOTES: SCM - Set Commissioning Mode for Module Enter MXL command: SCM 1 ON MLT m - MOI Lamp Test Enter MXL command: SCM 266 OFF Invalid Module CMC - Commissioning Mode Control XLT m - XLD-1 Point Annunciator (PAX) Lamp Test Enter MXL command: CMC TROUBLE IN 253 15:04:17 Feb 17, 1997...
HER - History Log Erase HON - History Logging On MXL-VDT 80/132 SETUP HAR - Arm/Disarm (Enable/ Disable) History Erasure Technical Manuals Online! - http://www.tech-man.com firealarmresources.com...
Page 14
Note: GENERAL SETUP TABS SETUP Characteristic Setting None required Emulation Wyse50+ Enhancements Virtual Term Scroll Style Jump ANSWERBACK SETUP Auto Scroll Auto Wrap Do NOT alter data in this menu. Received Data is preset at factory. Auto Page* Altering this data results in VDT Warning Bell supervision errors.
Page 15
COMMUNICATION SETUP Characteristic Setting Main Baud Rate Per CSG-M (default 1200 baud) Main Data/Parity Per CSG-M (default 8 data bits/no parity) Main Stop Bits Per CSG-M (default 1 stop bit) Ignore 8th Bit Main Rcv Hndsk None Main Xmt Hndsk None Comm Mode Full Duplex...
MXL-VDT 80/132 SETUP USING NOTE: The CSG-M selection for the termi- EITHER THE AUXILIARY OR nal for all three printers listed below must be either VDT-80 or VDT-132 PARALLEL PORT (unsupervised). GENERAL SETUP Setting Generic Characteristic Texas Inst C. Itoh Parallel TI-820KSR Cl-2500...
Page 17
COMMUNICATION SETUP Setting Generic Characteristic Texas Inst C. Itoh Parallel TI-820KSR Cl-2500 Printer Main Baud Rate Per CSG-M Per CSG-M Per CSG-M Main Data/Parity Per CSG-M Per CSG-M Per CSG-M Main Stop Bits Per CSG-M Per CSG-M Per CSG-M Ignore 8th Bit Main Rcv Hndsk None None...
Page 18
KEYBOARD SETUP Setting Generic Characteristic Texas Inst C. Itoh Parallel TI-820KSR Cl-2500 Printer Key Click Key Repeat Key Lock Caps Caps Caps Return Key Enter Key Back Space Key BS/DEL BS/DEL BS/DEL Left Alt Key Funct Funct Funct Break Xmt Limit None None None...
CABLING REQUIREMENTS FOR AUXILIARY PORT TO PRINTER LINK TERMINAL C. ITOH CI-2500 TI-820KSR (Aux port) pinouts pinouts pinouts DB-9 cable DB-25 cable DB-25 cable 1 DCD 8 Received line signal data 2 RXD 2 Send Data 2 TXD 3 TXD 3 Receive Data 3 RXD 4 DTR...
Page 20
TEXAS INSTRUMENTS TI-820KSR PRINTER Printer Settings Print Configuration (See Manual) (Typical) # characters per inch (16.5 CPI) Line spacing (8 single space 8 LPI) Bottom margin line number (001-112) Top margin line number (001-112) Right margin column number (001-218) Left margin column number (001-218) Form length in lines (001-112) TEXAS INSTRUMENTS TI-820KSR PRINTER Printer Settings...
MXL-VDT QUICK REFERENCE GUIDE t i r - - - - - - e l i e l i - - - a t l t f i - - - t f i - - - t f i - - - t f i y t i...
Page 22
t f i t n i t f i t n i , t u i t i t i v t f i v i t y t i , l a , l a , l a - - - t f i - - - - - -...
Page 23
v i t y t i - - - - - - v i t y t i t f / n i t t f / t f / v i t y t i t f / n i t t f / t f / - - -...
Page 24
* * l * * t * * t y t i i t c i t c y l l y l l y l l y l l NOTE: Technical Manuals Online! - http://www.tech-man.com firealarmresources.com...
Leave jumper G1 in place if the System printer is supervised. Cut jumper G1 if the System has an unsupervised printer. TB1 CONNECTIONS Figure 1 PIM-1 Connection Diagram Technical Manuals Online! - http://www.tech-man.com firealarmresources.com...