Siemens SIMATIC S7-1500R/H Equipment Manual
Hide thumbs Also See for SIMATIC S7-1500R/H:

Advertisement

Quick Links

Edition
11/2022
EQUIPMENT MANUAL
SIMATIC
S7-1500R/H
CPU 1517H-3 PN
6ES7517-3HP00-0AB0
support.industry.siemens.com

Advertisement

Table of Contents
loading

Summary of Contents for Siemens SIMATIC S7-1500R/H

  • Page 1 Edition 11/2022 EQUIPMENT MANUAL SIMATIC S7-1500R/H CPU 1517H-3 PN 6ES7517-3HP00-0AB0 support.industry.siemens.com...
  • Page 2 Introduction Safety instructions SIMATIC Product overview S7-1500R/H CPU 1517H-3 PN Connecting (6ES7517-3HP00-0AB0) Interrupts, diagnostics, error messages and system events Equipment Manual Technical specifications Dimension drawing 11/2022 A5E42011886-AD...
  • Page 3 Note the following: WARNING Siemens products may only be used for the applications described in the catalog and in the relevant technical documentation. If products and components from other manufacturers are used, these must be recommended or approved by Siemens. Proper transport, storage, installation, assembly, commissioning, operation and maintenance are required to ensure that the products operate safely and without any problems.
  • Page 4: Table Of Contents

    Table of contents Introduction............................S7-1500R/H Documentation Guide..................1.1.1 Information classes S7-1500R/H..................1.1.2 SIMATIC Technical Documentation..................Safety instructions..........................Security information......................Product overview..........................10 New functions........................10 Configuration and operating principle................14 Hardware properties......................15 Firmware functions......................18 Operator controls and display elements................20 3.5.1 Front view of the CPU with closed front flap..............
  • Page 5: Introduction

    Industry Mall The Industry Mall is the catalog and order system of Siemens AG for automation and drive solutions on the basis of Totally Integrated Automation (TIA) and Totally Integrated Power (TIP).
  • Page 6: S7-1500R/H Documentation Guide

    Changes and supplements to the manuals are documented in a Product Information. The Product Information takes precedence over the device and system manuals. You can find the latest Product Information on the redundant S7-1500R/H system on the Internet. (https://support.industry.siemens.com/cs/ww/en/view/109742691) CPU 1517H-3 PN (6ES7517-3HP00-0AB0) Equipment Manual, 11/2022, A5E42011886-AD...
  • Page 7: Simatic Technical Documentation

    Online Support: Industry Online Support International https://support.industry.siemens.com/cs/ww/en/view/109742705 Watch this short video to find out where you can find the overview directly in Siemens Industry Online Support and how to use Siemens Industry Online Support on your mobile device: Quick introduction to the technical documentation of automation products per video ( https://support.industry.siemens.com/cs/us/en/view/109780491...
  • Page 8 Manuals, characteristics, operating manuals, certificates • Product master data You can find "mySupport" on the Internet. (https://support.industry.siemens.com/My/ww/en) Application examples The application examples support you with various tools and examples for solving your automation tasks. Solutions are shown in interplay with multiple components in the system - separated from the focus on individual products.
  • Page 9: Safety Instructions

    Siemens' products and solutions undergo continuous development to make them more secure. Siemens strongly recommends that product updates are applied as soon as they are available and that the latest product versions are used. Use of product versions that are no longer supported, and failure to apply the latest updates may increase customers' exposure to cyber threats.
  • Page 10: Product Overview

    Support As of FW version V3.0, the S7-1500H redund­ • S7-1500R/H System Manual PROFINET system redundancy R1 ant system supports PROFINET system redund­ (https://support.industry. siemens. ancy R1: com/cs/ww/en/view/10975­ • ET 200SP IM 155-6 PN R1 4833) (6ES7155-6AU00-0HM0) • PROFINET Function Manual •...
  • Page 11 As of FW version V3.0, a new synchronization S7-1500R/H System Manual module Sync Module 1 GB FO 40 km is avail­ (https://support.industry. siemens. able. The synchronization module enables a com/cs/ww/en/view/10975483­ distance of up to 40 km between the two H- CPUs via optical fibers. This allows you to use the S7-1500H redundant system for long tun­...
  • Page 12 Customer benefits Where can I find information? Simulation of R/H-CPUs PLCSIM Advanced V4.0 supports simulation of R/H- S7-PLCSIM Advanced Function Manual CPUs (https://support.industry.siemens. com/cs/ww/en/view/109773484) • Virtual commissioning of machines with R/H-CPUs in a system • Automatic testing of the STEP 7 user program The simulation offers the following advantages: •...
  • Page 13 You can download a modified user program into the S7-1500R/H System Manual program in RUN-Redund­ R/H CPUs in the RUN-Redundant system state. (https://support.industry.siemens. ant system state Advantage: The redundant system will remain consist­ com/cs/ww/en/view/109754833) ently in the RUN-Redundant system state during the change to the user program.
  • Page 14: Configuration And Operating Principle

    3.2 Configuration and operating principle Additional information You can find an overview of all new functions, improvements and revisions in the respective firmware version on the Internet (https://support.industry.siemens.com/cs/ww/en/view/109478459). Configuration and operating principle Structure The S7-1500H redundant system consists of the following components: •...
  • Page 15: Hardware Properties

    You mount the CPUs on a standardized 35 mm rail using the standard rail adapter. You can find information on mounting the standard rail adapter in the S7‑1500R/H redundant system (https://support.industry.siemens.com/cs/ww/en/view/109754833) System Manual. Principle of operation One of the two CPUs in the redundant system takes on the role of CPU for process control (primary CPU).
  • Page 16 All CPUs of the redundant system S7 1500R/H have a dis­ • Redundant System S7‑1500R/H play with plain text information. The display provides (https://support.industry.siemens. you with diagnostic messages as well as information com/cs/ww/en/view/109754833) about the article number, the firmware version and the System Manual serial number of the CPU.
  • Page 17 The 24 V DC supply voltage is fed via a 4-pin plug located • Section Connecting (Page 26) on the front of the CPU. • Redundant System S7‑1500R/H (https://support.industry.siemens. com/cs/ww/en/view/109754833) System Manual PROFINET IO PROFINET IO interface The CPU has an X1 interface with two ports (X1 P1R and •...
  • Page 18: Firmware Functions

    There are two duplicate CPUs that synchronize their data Redundant System S7‑1500R/H via two duplex fiber-optic cables, which connect the (https://support.industry.siemens. CPUs directly to each other via plug-in synchronization com/cs/ww/en/view/109754833) Sys­ modules. If one of the CPUs fails, the other CPU retains tem Manual control of the process.
  • Page 19 Integrated technology Integrated closed-loop con­ • PID Compact (continuous PID controller) PID Control Function Manual trol functionality (https://support.industry.siemens. • PID 3Step (step controller for integrating actuators) com/cs/ww/en/view/108210036) • PID Temp (temperature controller for heating and cooling with two separate actuators) Controlling, measuring and •...
  • Page 20: Operator Controls And Display Elements

    Product overview 3.5 Operator controls and display elements Operator controls and display elements 3.5.1 Front view of the CPU with closed front flap The figure below shows the front view of the CPU 1517H‑3 PN. ① LEDs for the current operating state and diagnostic status of the CPU ②...
  • Page 21 (local lock) and assign a password for the display. You can find additional information on the display, the configurable protection levels and the local lock in the system manual for Redundant System S7‑1500R/H (https://support.industry.siemens.com/cs/ww/en/view/109754833). Reference You can find detailed information on the individual display options, a training course and a simulation of the available menu commands in the SIMATIC S7-1500 Display Simulator (https://support.industry.siemens.com/cs/ww/en/view/109761758).
  • Page 22: Front View Of The Cpu Without Front Flaps

    Product overview 3.5 Operator controls and display elements 3.5.2 Front view of the CPU without front flaps The figure below shows the operator controls and connection elements of the CPU 1517H‑3 PN. ① Mode selector ② No function ③ LED displays for the ports of the X3 and X4 interfaces ④...
  • Page 23: Rear View Of The Cpu

    Product overview 3.5 Operator controls and display elements 3.5.3 Rear view of the CPU The figure below shows the connection elements on the rear of the CPU 1517H‑3 PN. ① Shield contact surfaces ② Fixing screws Figure 3-6  View of the CPU 1517H‑3 PN - rear CPU 1517H-3 PN (6ES7517-3HP00-0AB0) Equipment Manual, 11/2022, A5E42011886-AD...
  • Page 24: Bottom View

    Product overview 3.6 Mode selector 3.5.4 Bottom view Interfaces and synchronization modules The figure below shows the position of the interfaces on the underside of the CPU. ① PROFINET IO interface X1 with 2 ports ② PROFINET IO interface X2 with 1 port ③...
  • Page 25 You can find a brief overview of the various operating states and system states in the section Status and error display of the CPU (Page 30). You can find a detailed description of the operating states and system states in the system manual for S7-1500R/H Redundant System (https://support.industry.siemens.com/cs/ww/en/view/109754833). CPU 1517H-3 PN (6ES7517-3HP00-0AB0) Equipment Manual, 11/2022, A5E42011886-AD...
  • Page 26: Connecting

    + 24 V DC of the supply voltage for loop-through 1L+ and 2L+ as well as 1M and 2M are bridged internally Maximum 10 A permitted You can find information on the various supply options in the system manual for Redundant System S7‑1500R/H (https://support.industry.siemens.com/cs/ww/en/view/109754833). CPU 1517H-3 PN (6ES7517-3HP00-0AB0) Equipment Manual, 11/2022, A5E42011886-AD...
  • Page 27 Connecting 4.1 Terminal assignment PROFINET interface X1 with 2-port switch (X1 P1R and X1 P2R) The assignment corresponds to the Ethernet standard for an RJ45 plug. • When autonegotiation is deactivated, the RJ45 socket is allocated as a switch (MDI-X). • When autonegotiation is activated, autocrossing is in effect and the RJ45 socket is allocated either as data terminal equipment (MDI) or a switch (MDI-X).
  • Page 28 Additional information You can find additional information on the topic of "Connecting the CPU" and on the topic "Accessories/spare parts" in the system manual for Redundant System S7‑1500R/H (https://support.industry.siemens.com/cs/ww/en/view/109754833). Assignment of the MAC addresses For each CPU, CPU 1517H‑3 PN has: • One PROFINET interface with two ports •...
  • Page 29 Connecting 4.1 Terminal assignment Block diagram The following figure shows the block diagram of the CPU 1517H‑3 PN. ① SIMATIC memory card (X50) PN X1 P2R PROFINET interface X1 port 2 ② Display PN X2 P1 PROFINET interface X2 port 1 ③ Mode selector RUN/STOP/MRES HSYNC X3 P1 H-Sync interface X3 port 1 ④...
  • Page 30: Interrupts, Diagnostics, Error Messages And System Events

    You can find more detailed information on "Interrupts" in the STEP 7 online help. You can find additional information on the topic of "Diagnostics" and "System events" in the Diagnostics (https://support.industry.siemens.com/cs/ww/en/view/59192926) function manual and in the system manual Redundant System S7‑1500R/H (https://support.industry.siemens.com/cs/ww/en/view/109754833).
  • Page 31 Interrupts, diagnostics, error messages and system events 5.1 Status and error display of the CPU LED displays depending on operating states and system states CPU 1517H‑3 PN has the following LEDs for displaying the current operating state and diagnostics status. • RUN/STOP LED •...
  • Page 32 Interrupts, diagnostics, error messages and system events 5.1 Status and error display of the CPU Meaning of the RUN/STOP, ERROR and MAINT LEDs CPU 1517H‑3 PN has the following LEDs for displaying the current operating state and diagnostics status. NOTE LED patterns of the S7-1500H redundant system Note that it is not always possible to: •...
  • Page 33 Interrupts, diagnostics, error messages and system events 5.1 Status and error display of the CPU RUN/STOP LED ERROR LED MAINT LED Meaning Maintenance demanded for the plant. LED lit green LED off LED lit yellow You need to check/replace the affected hardware within a short period of time.
  • Page 34 Interrupts, diagnostics, error messages and system events 5.1 Status and error display of the CPU LINK TX/RX LED Meaning The CPU performs an LED flash test. Flashes green There is a connection between the interface of the device and a communication partner. Illuminated green The redundancy connections are OK.
  • Page 35: Technical Specifications

    Technical specifications The following table shows the technical specifications as of 11/2022. You can find a data sheet including daily updated technical specifications on the Internet (https://support.industry.siemens.com/cs/ww/en/pv/6ES7517-3HP00-0AB0/td?dl=en). Article number 6ES7517-3HP00-0AB0 General information   Product type designation CPU 1517H-3 PN HW functional status...
  • Page 36 Technical specifications Article number 6ES7517-3HP00-0AB0 Work memory   • integrated (for program) 2 Mbyte integrated (for data) 8 Mbyte • Load memory   • Plug-in (SIMATIC Memory Card), max. 32 Gbyte Backup   maintenance-free • CPU processing times   for bit operations, typ. 4 ns for word operations, typ.
  • Page 37 Technical specifications Article number 6ES7517-3HP00-0AB0 S7 counter   • Number 2 048 Retentivity   adjustable – IEC counter   • Number Any (only limited by the main memory) Retentivity   adjustable – S7 times   • Number 2 048 Retentivity   adjustable –...
  • Page 38 Technical specifications Article number 6ES7517-3HP00-0AB0 Number of distributed IO systems Number of IO Controllers   • integrated Rack   Modules per rack, max. 1; CPU • Time of day   Clock   • Type Hardware clock Backup time 6 wk; At 40 °C ambient temperature, typically •...
  • Page 39 Technical specifications Article number 6ES7517-3HP00-0AB0 – Updating times The minimum value of the update time also depends on communication share set for PROFINET IO, on the number of IO devices, and on the quantity of configured user data Update time for RT  ...
  • Page 40 Technical specifications Article number 6ES7517-3HP00-0AB0 • PROFINET system redundancy (S2) • PROFINET system redundancy (R1) Media redundancy   – Yes; MRP Automanager according to IEC 62439-2 Edition 2.0 – MRP interconnection, supported Yes; as MRP ring node according to IEC 62439-2 Edition 3.0 MRPD –...
  • Page 41 Technical specifications Article number 6ES7517-3HP00-0AB0 S7 message functions   Number of login stations for message func­ tions, max. Program alarms Number of configurable program messages, 10 000; Program messages are generated by the max. "Program_Alarm" block, ProDiag or GRAPH Number of loadable program messages in 5 000 RUN, max.
  • Page 42 Technical specifications Article number 6ES7517-3HP00-0AB0 Supported technology objects   Motion Control Controller • PID_Compact Yes; Universal PID controller with integrated optimization • PID_3Step Yes; PID controller with integrated optimization for valves • PID-Temp Yes; PID controller with integrated optimization for temperature Counting and measuring •...
  • Page 43 2 094 g; Interface modules: 2x 18 g General technical specifications You can find information on the general technical specifications, such as standards and approvals, electromagnetic compatibility, protection class, etc. in the system manual for Redundant System S7‑1500R/H (https://support.industry.siemens.com/cs/ww/en/view/109754833). CPU 1517H-3 PN (6ES7517-3HP00-0AB0) Equipment Manual, 11/2022, A5E42011886-AD...
  • Page 44: Dimension Drawing

    Dimension drawing This section contains the dimension drawing of the module on the mounting rail, as well as a dimension drawing with the front panel open. Keep to the dimensions when installing in cabinets, control rooms, etc. Dimension drawings of the CPU 1517H‑3 PN Figure A-1  Dimension drawing of the CPU 1517H‑3 PN, front and side view Figure A-2  Dimension drawing of the CPU 1517H‑3 PN, side view with front panel open CPU 1517H-3 PN (6ES7517-3HP00-0AB0)

Table of Contents