Siemens SIMATIC S7-1500R/H Equipment Manual
Hide thumbs Also See for SIMATIC S7-1500R/H:

Advertisement

Quick Links

Edition
11/2022
EQUIPMENT MANUAL
SIMATIC
S7-1500R/H
CPU 1518HF-4 PN
6ES7518-4JP00-0AB0
support.industry.siemens.com

Advertisement

Table of Contents
loading

Summary of Contents for Siemens SIMATIC S7-1500R/H

  • Page 1 Edition 11/2022 EQUIPMENT MANUAL SIMATIC S7-1500R/H CPU 1518HF-4 PN 6ES7518-4JP00-0AB0 support.industry.siemens.com...
  • Page 2 Introduction Safety instructions SIMATIC Product overview S7-1500R/H CPU 1518HF-4 PN Connecting (6ES7518-4JP00-0AB0) Alarm, error and system messages Equipment Manual Technical specifications Dimension drawing 11/2022 A5E49868646-AB...
  • Page 3 Note the following: WARNING Siemens products may only be used for the applications described in the catalog and in the relevant technical documentation. If products and components from other manufacturers are used, these must be recommended or approved by Siemens. Proper transport, storage, installation, assembly, commissioning, operation and maintenance are required to ensure that the products operate safely and without any problems.
  • Page 4: Table Of Contents

    Table of contents Introduction............................S7-1500R/H Documentation Guide..................1.1.1 Information classes S7-1500R/H..................1.1.2 SIMATIC Technical Documentation..................Safety instructions..........................Security information......................Product overview..........................10 New functions........................10 Configuration and operating principle................11 Hardware properties......................13 Firmware functions......................16 Operator controls and display elements................18 3.5.1 Front view of the CPU with closed front flap..............
  • Page 5: Introduction

    Industry Mall The Industry Mall is the catalog and order system of Siemens AG for automation and drive solutions on the basis of Totally Integrated Automation (TIA) and Totally Integrated Power (TIP).
  • Page 6: S7-1500R/H Documentation Guide

    Changes and supplements to the manuals are documented in a Product Information. The Product Information takes precedence over the device and system manuals. You can find the latest Product Information on the redundant S7-1500R/H system on the Internet. (https://support.industry.siemens.com/cs/ww/en/view/109742691) CPU 1518HF-4 PN (6ES7518-4JP00-0AB0) Equipment Manual, 11/2022, A5E49868646-AB...
  • Page 7: Simatic Technical Documentation

    Online Support: Industry Online Support International https://support.industry.siemens.com/cs/ww/en/view/109742705 Watch this short video to find out where you can find the overview directly in Siemens Industry Online Support and how to use Siemens Industry Online Support on your mobile device: Quick introduction to the technical documentation of automation products per video ( https://support.industry.siemens.com/cs/us/en/view/109780491...
  • Page 8 Manuals, characteristics, operating manuals, certificates • Product master data You can find "mySupport" on the Internet. (https://support.industry.siemens.com/My/ww/en) Application examples The application examples support you with various tools and examples for solving your automation tasks. Solutions are shown in interplay with multiple components in the system - separated from the focus on individual products.
  • Page 9: Safety Instructions

    Siemens' products and solutions undergo continuous development to make them more secure. Siemens strongly recommends that product updates are applied as soon as they are available and that the latest product versions are used. Use of product versions that are no longer supported, and failure to apply the latest updates may increase customers' exposure to cyber threats.
  • Page 10: Product Overview

    Where can I find information? Support As of FW version V3.0, the S7-1500H redundant • S7-1500R/H System Manual PROFINET system redundancy R1 system supports PROFINET system redundancy (https://support.industry. siemens. com/cs/ww/en/view/109754­ • ET 200SP IM 155-6 PN R1 833) (6ES7155-6AU00-0HM0) • PROFINET Function Manual •...
  • Page 11: Configuration And Operating Principle

    As of FW version V3.0, a new synchronization S7-1500R/H System Manual module Sync Module 1 GB FO 40 km is available. (https://support.industry. siemens. The synchronization module enables a distance com/cs/ww/en/view/109754833) of up to 40 km between the two H-CPUs via optical fibers. This allows you to use the S7-1500H redundant system for long tunnel installations.
  • Page 12 You mount the CPUs on a standardized 35 mm rail using the standard rail adapter. You can find information on mounting the standard rail adapter in the S7‑1500R/H redundant system (https://support.industry.siemens.com/cs/ww/en/view/109754833) System Manual. Principle of operation One of the two CPUs in the redundant system takes on the role of CPU for process control (primary CPU).
  • Page 13: Hardware Properties

    CPUs via plug-in synchronization modules. The integrated F functionality with Safety Integrated processes standard and safety programs. You can find more information in the SIMATIC Safety - Configuring and Programming (https://support.industry.siemens.com/cs/ww/en/view/54110126) programming and operating manual. Additional information You can find a detailed description of the operation and design of the S7‑1500H redundant system in the system manual for Redundant System S7-1500R/H (https://support.industry.siemens.com/cs/ww/en/view/109754833).
  • Page 14 All CPUs of the redundant system S7 1500R/H have a dis­ • Redundant System S7‑1500R/H play with plain text information. The display provides (https://support.industry.siemens. you with diagnostic messages as well as information com/cs/ww/en/view/109754833) about the article number, the firmware version and the System Manual serial number of the CPU.
  • Page 15 The 24 V DC supply voltage is fed via a 4-pin plug located • Section Connecting (Page 24) on the front of the CPU. • Redundant System S7‑1500R/H (https://support.industry.siemens. com/cs/ww/en/view/109754833) System Manual PROFINET IO PROFINET IO interface The CPU has an X1 interface with two ports (X1 P1R and •...
  • Page 16: Firmware Functions

    There are two duplicate CPUs that synchronize their data Redundant System S7‑1500R/H via two duplex fiber-optic cables, which connect the (https://support.industry.siemens. CPUs directly to each other via plug-in synchronization com/cs/ww/en/view/109754833) Sys­ modules. If one of the CPUs fails, the other CPU retains tem Manual control of the process.
  • Page 17 Additional information Switched S1 device The switched S1 device function of the CPU enables Redundant System S7‑1500R/H operation of standard IO devices in the S7‑1500R/H (https://support.industry.siemens. redundant system. com/cs/ww/en/view/109754833) Sys­ tem Manual RT (real time) RT prioritizes PROFINET IO frames over standard frames.
  • Page 18: Operator Controls And Display Elements

    Description Additional information tion of engineering data detected by the integrity protec­ Redundant System S7‑1500R/H tion. (https://support.industry.siemens. com/cs/ww/en/view/109754833) Sys­ Password provider As an alternative to manual password entry, you can link tem Manual a password provider to STEP 7. A password provider offers the following advantages: •...
  • Page 19 (local lock) and assign a password for the display. You can find additional information on the display, the configurable protection levels and the local lock in the system manual for Redundant System S7‑1500R/H (https://support.industry.siemens.com/cs/ww/en/view/109754833). CPU 1518HF-4 PN (6ES7518-4JP00-0AB0) Equipment Manual, 11/2022, A5E49868646-AB...
  • Page 20: Front View Of The Cpu Without Front Flaps

    Reference You can find detailed information on the individual display options, a training course and a simulation of the available menu commands in the SIMATIC S7-1500 Display Simulator (https://support.industry.siemens.com/cs/ww/en/view/109761758). 3.5.2 Front view of the CPU without front flaps The figure below shows the operator controls and connection elements of CPU 1518HF‑4 PN.
  • Page 21: Rear View Of The Cpu

    Product overview 3.5 Operator controls and display elements 3.5.3 Rear view of the CPU The following figure shows the connection elements on the rear of CPU 1518HF‑4 PN. ① Shield contact surfaces ② Fixing screws Figure 3-6  View of CPU 1518HF‑4 PN - rear CPU 1518HF-4 PN (6ES7518-4JP00-0AB0) Equipment Manual, 11/2022, A5E49868646-AB...
  • Page 22: Bottom View

    Product overview 3.6 Mode selector 3.5.4 Bottom view Interfaces and synchronization modules The figure below shows the position of the interfaces on the underside of the CPU. ① PROFINET IO interface X2 with 1 port ② PROFINET IO interface X3 with 1 port ③...
  • Page 23 You can find a brief overview of the various operating states and system states in the section Status and error display of the CPU (Page 29). You can find a detailed description of the operating states and system states in the system manual for S7-1500R/H Redundant System (https://support.industry.siemens.com/cs/ww/en/view/109754833). CPU 1518HF-4 PN (6ES7518-4JP00-0AB0) Equipment Manual, 11/2022, A5E49868646-AB...
  • Page 24: Connecting

    1L+ and 2L+ as well as 1M and 2M are bridged internally Maximum 10 A permitted You can find information on the various supply options in the system manual for Redundant System S7‑1500R/H (https://support.industry.siemens.com/cs/ww/en/view/109754833). CPU 1518HF-4 PN (6ES7518-4JP00-0AB0) Equipment Manual, 11/2022, A5E49868646-AB...
  • Page 25 Connecting 4.1 Terminal assignment PROFINET interface X1 with 2-port switch (X1 P1R and X1 P2R) The assignment corresponds to the Ethernet standard for an RJ45 plug. • When autonegotiation is deactivated, the RJ45 socket is allocated as a switch (MDI-X). • When autonegotiation is activated, autocrossing is in effect and the RJ45 socket is allocated either as data terminal equipment (MDI) or a switch (MDI-X).
  • Page 26 Additional information You can find additional information on the topic of "Connecting the CPU" and on the topic "Accessories/spare parts" in the system manual for Redundant System S7‑1500R/H (https://support.industry.siemens.com/cs/ww/en/view/109754833). Assignment of the MAC addresses CPU 1518HF‑4 PN has for each CPU: • One PROFINET interface with two ports •...
  • Page 27 Connecting 4.1 Terminal assignment Assignment Labeling MAC address 2 Port X1 P1R (required for LLDP, for example) MAC address 3 Port X1 P2R (required for LLDP, for example) MAC address 4 PROFINET interface X2 • Front printed (visible in STEP 7 when devices are accessible) MAC address 5 Port X2 P1 (required for LLDP, for example) MAC address 6...
  • Page 28 Connecting 4.1 Terminal assignment ⑤ PROFINET 2-port switch 24 V DC supply voltage ⑥ Synchronization interface Ground ⑦ Backplane bus connection RUN/STOP LED (yellow/green) (connection to backplane bus not configur­ able) ⑧ Internal supply voltage ERROR LED (red) ⑨ Supply of the 24 V DC supply voltage (X80) MT MAINT LED (yellow) PN X1 P1R PROFINET interface X1 port 1...
  • Page 29: Alarm, Error And System Messages

    You can find more detailed information on "Interrupts" in the STEP 7 online help. You can find additional information on the topic of "Diagnostics" and "System events" in the Diagnostics (https://support.industry.siemens.com/cs/ww/en/view/59192926) function manual and in the system manual Redundant System S7‑1500R/H (https://support.industry.siemens.com/cs/ww/en/view/109754833).
  • Page 30 Alarm, error and system messages 5.1 Status and error display of the CPU LED displays depending on operating states and system states CPU 1518HF‑4 PN has the following LEDs for displaying the current operating state and diagnostics status. • RUN/STOP LED • ERROR LED •...
  • Page 31 Alarm, error and system messages 5.1 Status and error display of the CPU Meaning of the RUN/STOP, ERROR and MAINT LEDs CPU 1518HF‑4 PN has three LEDs for displaying the current operating state and diagnostics status. NOTE LED patterns of the S7-1500H redundant system Note that it is not always possible to: •...
  • Page 32 Alarm, error and system messages 5.1 Status and error display of the CPU RUN/STOP LED ERROR LED MAINT LED Meaning Maintenance demanded for the plant. LED lit green LED off LED lit yellow You need to check/replace the affected hardware within a short period of time.
  • Page 33 Alarm, error and system messages 5.1 Status and error display of the CPU LINK TX/RX LED Meaning The CPU performs an LED flash test. Flashes green There is a connection between the interface of the device and a communication partner. Illuminated green The redundancy connections are OK.
  • Page 34: Technical Specifications

    Technical specifications The following table shows the technical specifications as of 11/2022. You can find a data sheet including daily updated technical specifications on the Internet (https://support.industry.siemens.com/cs/ww/en/pv/6ES7518-4JP00-0AB0/td?dl=en). Article number 6ES7518-4JP00-0AB0 General information   Product type designation CPU 1518HF-4PN HW functional status...
  • Page 35 Technical specifications Article number 6ES7518-4JP00-0AB0 SIMATIC memory card required Work memory   • integrated (for program) 9 Mbyte integrated (for data) 60 Mbyte • Load memory   • Plug-in (SIMATIC Memory Card), max. 32 Gbyte Backup   maintenance-free • CPU processing times   for bit operations, typ.
  • Page 36 Technical specifications Article number 6ES7518-4JP00-0AB0 Nesting depth   • per priority class 24; Up to 8 possible for F-blocks Counters, timers and their retentivity   S7 counter   Number 2 048 • Retentivity   – adjustable IEC counter   Number Any (only limited by the main memory) •...
  • Page 37 Technical specifications Article number 6ES7518-4JP00-0AB0 Subprocess images   • Number of subprocess images, max. Hardware configuration   Number of distributed IO systems Number of IO Controllers   integrated • Rack   • Modules per rack, max. 1; CPU Time of day  ...
  • Page 38 Technical specifications Article number 6ES7518-4JP00-0AB0 – Number of connectable IO Devices, max. – Updating times The minimum value of the update time also depends on communication share set for PROFINET IO, on the number of IO devices, and on the quantity of configured user data Update time for RT  ...
  • Page 39 Technical specifications Article number 6ES7518-4JP00-0AB0 • 100 Mbps • 1000 Mbps Yes; Only possible at the X3 interface of the CPU 1518 • Autonegotiation Autocrossing • • Industrial Ethernet status LED Protocols   PROFIsafe Yes; V2.4 / V2.6 Number of connections  ...
  • Page 40 Technical specifications Article number 6ES7518-4JP00-0AB0 – Data length, max. 2 kbyte; 1 472 bytes for UDP broadcast – UDP multicast Yes; 128 multicast circuits (of which max. 5 via • DHCP • • SNMP • • LLDP Web server   HTTP •...
  • Page 41 Technical specifications Article number 6ES7518-4JP00-0AB0 • Forcing Yes; without fail-safe • Forcing, variables peripheral inputs/outputs (without fail-safe) • Number of variables, max. Diagnostic buffer   • present • Number of entries, max. 3 200 – of which powerfail-proof 1 000 Traces   Number of configurable Traces •...
  • Page 42 Technical specifications Article number 6ES7518-4JP00-0AB0 • horizontal installation, min. 0 °C • horizontal installation, max. 60 °C; Display: 50 °C, at an operating temperature of typically 50 °C, the display is switched off • vertical installation, min. 0 °C vertical installation, max. 40 °C; Display: 40 °C, at an operating temperature •...
  • Page 43 2 116 g General technical specifications You can find information on the general technical specifications, such as standards and approvals, electromagnetic compatibility, protection class, etc. in the system manual for Redundant System S7‑1500R/H (https://support.industry.siemens.com/cs/ww/en/view/109754833). CPU 1518HF-4 PN (6ES7518-4JP00-0AB0) Equipment Manual, 11/2022, A5E49868646-AB...
  • Page 44: Dimension Drawing

    Dimension drawing This section contains the dimension drawing of the module on the mounting rail, as well as a dimension drawing with the front panel open. Keep to the dimensions when installing in cabinets, control rooms, etc. Dimension drawings of the CPU 1518HF‑4 PN Figure A-1  Dimension drawing of the CPU 1518HF‑4 PN, front and side view Figure A-2  Dimension drawing of the CPU 1518HF‑4 PN, side view with front panel open CPU 1518HF-4 PN (6ES7518-4JP00-0AB0)

Table of Contents