Replacing The Plug - Siemens SCALANCE S615 Operating Instructions Manual

Simatic net industrial ethernet security
Hide thumbs Also See for SCALANCE S615:
Table of Contents

Advertisement

Connecting up

5.6 Replacing the PLUG

5.6
Replacing the PLUG
NOTICE
Do not remove or insert a C-PLUG / KEY-PLUG during operation!
A PLUG may only be removed or inserted when the device is turned off.
The device checks whether or not a PLUG is present at one second intervals. The device
restarts if it is detected that the PLUG has been removed.
If a valid KEY-PLUG was inserted in the device, the device changes to a defined error state
following the restart.
Inserting the PLUG
1. Turn off the power to the device.
2. Insert the PLUG correctly oriented into the slot.
To ensure this, the housing of the PLUG has a protruding ridge on the long side. The slot
has a groove at this position.
56
Operating Instructions, 10/2022, C79000-G8976-C389-07
SCALANCE S615

Advertisement

Table of Contents
loading

Table of Contents