Tx Format Dest 1; Swinger Dialler; Myalarm Options - Bosch Solution 6000-IP CC615GWF Quick Start Manual

Hide thumbs Also See for Solution 6000-IP CC615GWF:
Table of Contents

Advertisement

Solution 6000-IP
Quick Start Guide
Comms > Reporting >

TX Format Dest 1

00 - Disabled
13 - Ethernet/WiFi
15 - MyAlarm IP
Use [] and [] keys or enter 0 – 15 then press [OK] to
program the transmission format the control panel will
use to report to Destination 1. Only 1 option can be
programmed.
Comms > Reporting >
TX Format Dest 2
00 - Disabled
13 - Ethernet/WiFi
15 - MyAlarm IP
Use [] and [] keys or enter 0 – 15 then press [OK] to
program the transmission format the control panel will
use to report to Destination 2. Only 1 option can be
programmed.
Comms > Reporting
Test Route
00 - Log Events Only
01 - Dest 1 + Log
02 - Dest 2 + Log
03 - Dest 1 & 2 + Log
04 - Dest 2 If 1 Fails
Use [] and [] keys or enter 0 - 4 + [OK]. Enter single
option only. (*** System Wide Parameter ***).
Comms > Reporting
System Route
00 - Log Events Only
01 - Dest 1 + Log
02 - Dest 2 + Log
03 - Dest 1 & 2 + Log
04 - Dest 2 If 1 Fails
Use [] and [] keys or enter 0 - 4 + [OK]. Enter single
option only. (*** System Wide Parameter ***).
Comms > Reporting
Emergency Route
00 - Log Events Only
01 - Dest 1 + Log
02 - Dest 2 + Log
03 - Dest 1 & 2 + Log
04 - Dest 2 If 1 Fails
Use [] and [] keys or enter 0 - 4 + [OK]. Enter single
option only. (*** System Wide Parameter ***).
38
MENU 5-4-0
0 0
01 ~ 12 Reserved
14 - GPRS IP
MENU 5-4-1
0 0
01 ~ 12 Reserved
14 - GPRS IP
MENU 5-4-2
0 1
MENU 5-4-3
0 1
MENU 5-4-4
0 1
Comms > Reporting >

Swinger Dialler

(*** System Wide Parameter ***)
Enter 0 – 15 + [OK] to program number of times the dialler
can report before lockout. 0 = Unlimited.
Comms > Reporting >
Burg Report Delay
(*** System Wide Parameter ***)
Enter 0 – 255 seconds + [OK] to program the delay time in
seconds before reports are sent. 0 = No Delay.
Comms > Reporting >
Fire Report Delay
(*** System Wide Parameter ***)
Enter 0 – 255 seconds + [OK] to program the delay time in
seconds before reports are sent. 0 = No Delay.
Comms > MyAlarm >
IP Address
1
0 0 0
Dest Nº 1
Factory Set. Do not change unless advised to do so by the
manufacturer.
Comms > MyAlarm >
IP Port
Factory Set. Do not change unless advised to do so by the
manufacturer.
Comms > MyAlarm >

MyAlarm Options

1 Disp Eth/WiFi Poll Fail
2 Rpt Eth/WiFi Poll Fail
3 Disp Cellular Poll Fail
4 Rpt Cellular Poll Fail
5 Disable Eth/WiFi MyAlar
6 Reserved
7 Reserved
8 Static IP
MENU 5-4-5
MENU 5-4-6
Seconds
MENU 5-4-7
Seconds
MENU 5-5-0
Digits
0 0 0
0 0 0
MENU 5-5-1
0 9 0 5 0
MENU 5-5-2
Bosch Security Systems 10/22 BLCC615R
0 6
0 0 0
0 0 0
12
0 0 0
N
N
N
N
N
N
N
N