7
REVIEW OF INSTALLATION ENVIRONMENT
Motor
capacity (kW)
0.4
0.75
1.5
2.2
3.7
5.5
7.5
11
15
18.5
22
30
37
45
55
75
90
110
132
160
185
220
250
280
315
355
400
450
500
560
(Note) The heat amount of the 7.5 K or lower built-in brake resistor is not included.
7.3 Problems and measures when using inverter
118
Table 7.6 Amount of heat generated by the inverter and reactor
FR-A800
Inverter heat amount
(W)
200 V
400 V
50
50
70
65
110
75
140
100
190
150
260
200
360
250
520
300
670
400
770
550
940
650
1050
800
1270
1100
1610
1300
1880
1550
2530
1900
3110
2400
2500
3000
4000
4200
5000
5500
6500
7000
8000
9000
10500
11500
Reactor
heat amount (W)
FR-HEL
200 V
400 V
6
6
7
7
8
8
11
11
13
13
17
17
19
19
23
23
26
26
29
29
34
34
38
38
47
47
47
47
52
52
130
130
130
130
160
140
140
170
230
240
270
300
360
360
450
450
470
500
(at the rated output)
FR-HAL
200 V
400 V
10
16
14
23
20
30
24
43
33
46
40
52
46
52
60
60
75
60
74
76
82
74
97
91
120
97
140
140
140
150
170
180
280
200
400
490
530
1080