ABB LineStrong2 Series Original Instructions Manual page 23

Emergency stop grab wire safety switchs
Table of Contents

Advertisement

Safety-related characteristic data and Conformity
Conformity
EN ISO13849-1
EN 62061
Safety data
Mechanical reliability B
10d
PFH
D
Proof test interval (life)
MTTF
d
Certifications
Information with regard to UL 508
2TLC172248M0201, rev. C
2020-11-11
European Machinery Directive 2006/42/EC
EN ISO 12100:2010, EN ISO 13850:2008, EN 60204-1:2006+A1:2009
EN 60947-1:2007+A1:2011, EN 60947-5-1:2004+A1:2009, EN 60947-5-
5:1997+A1:2005
Up to PL e, Cat. 4 depending upon system architecture
Up to SIL3 depending upon system architecture
6
1.5 x 10
operations at 100mA load
-7
<1.0x10
21 years
214 years (8 cycles per hour/24 hours per day/365 days)
TÜV, cULus
Use 12AWG copper conductors only
Electrical Rating: A300 48W5
Type 1 Enclosure
Max. Switching Current / Volt / Amp: 120V 6A (720VA break) PF 0.38,
240V 3A (720VA break) PF 0.38
23
www.abb.com/jokabsafety

Advertisement

Table of Contents
loading

Table of Contents