Configure

5.1
Configure
Configure
You configure the IM 155-5 PN HF interface module with STEP 7 or the configuration
software of another manufacturer.
Configuration software
STEP 7 (TIA Portal)
TIA Portal V16 with HSP0318
for the active backplane bus ST 1+12
TIA Portal V16 with HSP0334
for the active backplane bus ST 1+8 and the active backplane
bus ST 1+4
-
Insert the interface module IM 155-5 PN HF in slot 1.
Insert the I/O modules on slots 2 to 13.
Note
GSD file
When configuring using a GSD file, more I/O modules can be configured than can be
physically inserted. If you configure more I/O modules than can be inserted, the IM 155-5 PN
HF sends the message "Module cannot be reached".
Note
GSD file and 70 mm wide system power supply
When you are plugging a 70 mm wide system power supply, note that this system power
supply physically occupies two slots. When configuring using the GSD file, you must then
leave an empty slot after the system power supply in the configuration. Otherwise, the
IM 155-5 PN HF interface module reports the setpoint/actual difference as a "Configuration
error".
Active backplane bus ST 1+12 slot, active backplane bus ST 1+8 slot, active backplane bus ST 1+4 slot
Equipment Manual, 07/2020, A5E46240468-AB
GSD file
GSDML V2.34
for the active backplane bus ST 1+12
GSDML V2.35
for the active backplane bus ST 1+8 and the active
backplane bus ST 1+4
"Insert" the active backplane bus on slot 0.
5
17