Switching on the anti-condensation heater
Switch on any anti-condensation heating while the machine is not being
operated.
Taking the machine out of service
Details regarding the necessary measures, Chapter (Page 5).
Lubricating before recommissioning
NOTICE
Dry running bearings
Bearings can be damaged if they do not have sufficient grease.
• Re-grease the bearings if they have been out of service for more than one
!
Explosion hazard
If the anti-condensation heating is switched on directly after the machine is
switched off, the temperature class or the maximum surface temperature of
the machine can be exceeded.
In an explosive atmosphere, there is a risk of an explosion. This can result in
death, serious injury or material damage.
• Only switch on the anti-condensation heating after the motor has been
6.5.1
Avoidance of damage to rolling bearings during stoppages
6.6
Faults
6.6.1
Inspections in the event of faults
Natural disasters or unusual operating conditions, such as overloading
or short circuit, are faults that overload the machine electrically or
mechanically.
Immediately perform an inspection after such faults.
Correct the cause of the fault as described in the respective remedial
measures section. Repair any damage to the machine.
year. The shaft must rotate so that the grease can be distributed in the
bearings. Observe the data on the lubricant plate.
WARNING
switched off. Carefully comply with the data on the anti-condensation
heating plate.