5.2 - POSITIONS OF CONNECTORS

Fig. 5
REFERENCE
XC01
USER INTERFACE
XC02
HOB COMMUNICATION
DIGITAL IMPUTS (PIN 1 & 2 DOOR SWITCH, PIN 3 & 4
XI01
TELESCOPIC RUNNER SWITCH)
XP01
GROUND
XP02
POWER SUPPLY (NEUTRAL)
XP06
SIDEKLICK
XP07
POWER SUPPLY (PHASE)
XR01
SMALL LOADS
XR02
TOP/
XR03
MAIN RELAY (IN)
XR04
OPEN (*)
XR05
RING HEATER
XR06
MAIN RELAY KR01 (OUT)
XR07
MAIN RELAY KR01 (OUT)
XR08
MAIN RELAY KR01 (IN)
XR09
DOORLOCK SYSTEM
XR10
BOTTOM HEATER
XR11
FPM RELAY
XT01
PT500 SENSOR
XU01
FACTORY PROGRAMMING
XW01
ANALOG IMPUT (EXTERNAL NTC SENSOR)
XW02
FPM COMMUNICATION
(*) NOTE : Depends on the type of appliance, refer to the wiring diagram specific.
Technical Support - BSP
DESCRIPTION
11/47
CONNECTOR
WHITE
WHITE
ON PCB
FASTON
FASTON
ON PCB
FASTON
WHITE
FASTON
FASTON
FASTON
FASTON
FASTON
FASTON
FASTON
BLACK
FASTON
ON PCB
WHITE
ON PCB
ON PCB
ON PCB
599 73 09-98 Rev. 02

Hide quick links:

Advertisement

Table of Contents
loading