Operation; Smile 11Ea As-I; Smile 11Sa As-I; Led Indication - ABB Smile 11EA AS-i Original Instructions Manual

Emergency stop with safe as-i input slave
Hide thumbs Also See for Smile 11EA AS-i:
Table of Contents

Advertisement

5

Operation

Smile 11EA AS-i

Emergency stop:
Push the emergency stop button. An actuating force of 22 ± 4 N is required and the actuator travel is approximately
4 mm to latch.
Unlatch emergency stop button:
Turn the button clockwise until the button is unlatched.

Smile 11SA AS-i

Safety stop:
Push the safety stop button. An actuating force of 22 ± 4 N is required and the actuator travel is approximately 4
mm to latch.
Unlatch safety stop button:
Turn the button clockwise until the button is unlatched.

LED indication

The LED indication is identical on both models (Smile 11EA AS-i and Smile 11SA AS-i).
LED in pushbutton:
The LED indication is programmed individually in the PLC-program according to the table below.
LED
Indication
ON
Red
OFF
ON
Green
OFF
AS-i LED and Fault LED in combination:
LED pair by the M12-connector.
AS-i (Green)
OFF
ON
ON
Flash
2TLC172094M0201, rev. B
2012-08-03
Description
Out bit 1 ON
Out bit 1 OFF or Out bit 1&2 ON.
Out bit 2 ON
Out bit 2 OFF or Out bit 1&2 ON.
Fault (Red)
Description
OFF
AS-i power missing
OFF
Normal operation
ON
No data exchange with master
ON
No data exchange because address = 0
8
www.abb.com/lowvoltage

Advertisement

Table of Contents
loading

This manual is also suitable for:

Smile 11sa as-i

Table of Contents